首页> 外文期刊>BMC Urology >A microbiological evaluation of level of disinfection for flexible cystoscopes protected by disposable endosheaths
【24h】

A microbiological evaluation of level of disinfection for flexible cystoscopes protected by disposable endosheaths

机译:一次性使用鞘管保护的柔性膀胱镜消毒水平的微生物学评估

获取原文
   

获取外文期刊封面封底 >>

       

摘要

Background Flexible cystoscopy is used in urological outpatient departments for diagnostic cystoscopy of bladder cancer and requires a high-level disinfection between each patient. The purpose of this study was to make a microbiological post disinfection efficacy assessment of flexible cystoscopes (FC) using disposable sterile endosheaths. Methods One hundred endosheaths underwent a leak-test for barrier integrity after cystoscopy. Microbiological samples from these cystoscopies were obtained; after removal of the endosheath, and after cleaning the scope with a detergent cloth, rinsing with tap water followed by 70% ethanol disinfection and subsequent drying. The number of colony forming units (cfu) from the samples was counted after 72?hours and then divided in three categories, Clean FC (50?cfu/sample). The result was compared with data of 10?years continuous control sampling recorded in the Copenhagen Clean-Endoscope Quality Control Database (CCQCD) and analyzed with a Chi-square test for homogeneity. Results All 100 endosheaths passed the leak-test. All samples showed a Clean FC and low means of cfu. A query to the CCQCD, showed that 99.8% (1264/1267) of all FC with a built-in work-channel reprocessed in a WD were clean before use. Conclusion The reprocessing of FC using endosheaths, as preformed in this study, provides a patient-ready procedure. The results display a reprocessing procedure with low risk of pathogen transmission, high patient safety and a valid alternative to the recommended high-level disinfection procedure of FC. However, the general impression was that sheaths slightly reduced vision and resulted in some patient discomfort.
机译:背景技术柔性膀胱镜在泌尿外科门诊中用于膀胱癌的诊断性膀胱镜检查,并且需要在每个患者之间进行高水平的消毒。这项研究的目的是使用一次性无菌内护套对柔性膀胱镜(FC)进行微生物后消毒功效评估。方法膀胱镜检查后,对一百个内鞘进行渗漏测试以检查屏障完整性。从这些膀胱镜检查中获得了微生物样本;去除内鞘后,再用清洁布清洁示波器,然后用自来水冲洗,然后用70%乙醇消毒,然后干燥。 72小时后,对样本中的菌落形成单位(cfu)进行计数,然后将其分为三类:清洁FC(50?cfu /样本)。将结果与哥本哈根清洁内窥镜质量控制数据库(CCQCD)中记录的10年连续控制采样数据进行比较,并通过卡方检验进行同质性分析。结果全部100个内鞘均通过了泄漏测试。所有样品均显示清洁的FC和较低的cfu平均值。对CCQCD的查询显示,使用WD重新处理的带有内置工作通道的所有FC中,有99.8%(1264/1267)是干净的。结论:如本研究所述,使用内鞘对FC进行再处理,可为患者准备就绪的程序。结果显示出一种再处理程序,其病原体传播风险低,患者安全性高,并且是FC推荐的高级消毒程序的有效替代方法。但是,总的印象是护套略微降低了视力,并导致一些患者不适。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号