首页> 外文期刊>Biomedical Sciences >Accuracy of a Factory Calibrated Retrospective CGM Device and the Comparison to a Conventionally Calibrated Retrospective CGM Device: A Pilot Study
【24h】

Accuracy of a Factory Calibrated Retrospective CGM Device and the Comparison to a Conventionally Calibrated Retrospective CGM Device: A Pilot Study

机译:工厂校准的回顾性CGM设备的准确性以及与常规校准的回顾性CGM设备的比较:一项初步研究

获取原文
           

摘要

Objective: This study aimed to examine the accuracy of FreeStyle Libre Pro, a factory calibrated retrospective continuous glucose monitoring (CGM) device, and compare its measurements to those by iPro2, a conventionally calibrated retrospective CGM device. Methods: FreeStyle Libre Pro and iPro2 were simultaneously used in 15 patients with type 2 diabetes mellitus. As these devices have different sensor duration, data from the initial 168 hours period were used. Finger prick glucose tests were performed using a conventional glucose meter, OneTouch UltraVue. The mean absolute relative difference (MARD) and mean absolute difference (MAD) of FreeStyle Libre Pro compared to conventional finger prick blood glucose tests were calculated. Furthermore, the paired glucose measurements obtained by FreeStyle Libre Pro and iPro2 were compared. Results: Overall MARD of FreeStyle Libre Pro was 17.4%, and, when limited to range ≥ 100 mg/dl, MARD was 16.8%. Overall MAD of FreeStyle Libre Pro was 32.0 mg/dl, and, when limited to range 100 mg/dl, MAD was 21.1 mg/dl. Mean glucose measurements obtained by FreeStyle Libre Pro were significantly lower than those obtained by iPro2 (151.3±60.4 mg/dl vs. 179.4±64.1 mg/dl, P 0.01). Linear regression analysis revealed significant correlation between glucose measurements obtained by FreeStyle Libre Pro and those obtained by iPro2: Glucose (FreeStyle Libre Pro) (mg/dl) = 0.86 × Glucose (iPro2) - 3.31 (mg/dl), r = 0.914, P 0.01. Conclusions: FreeStyle Libre Pro is convenient to use because it does not need calibration by finger prick glucose tests, however our results supports the importance of confirming the measurements of FreeStyle Libre Pro by conventional finger prick glucose tests or central laboratory tests.
机译:目的:本研究旨在检查出厂校准的回顾性连续血糖监测(CGM)设备FreeStyle Libre Pro的准确性,并将其测量值与常规校准的回顾性CGM设备iPro2进行比较。方法:FreeStyle Libre Pro和iPro2同时用于15例2型糖尿病患者。由于这些设备的传感器持续时间不同,因此使用了最初168小时的数据。使用常规血糖仪OneTouch UltraVue进行手指点刺葡萄糖测试。计算了FreeStyle Libre Pro与常规手指刺血糖测试相比的平均绝对相对差异(MARD)和平均绝对差异(MAD)。此外,比较了FreeStyle Libre Pro和iPro2获得的配对葡萄糖测量值。结果:FreeStyle Libre Pro的总体MARD为17.4%,并且当范围≥100 mg / dl时,MARD为16.8%。 FreeStyle Libre Pro的总MAD为32.0 mg / dl,当限制在<100 mg / dl时,MAD为21.1 mg / dl。 FreeStyle Libre Pro获得的平均血糖测量值显着低于iPro2获得的平均血糖测量值(151.3±60.4 mg / dl与179.4±64.1 mg / dl,P <0.01)。线性回归分析显示,通过FreeStyle Libre Pro获得的葡萄糖测量值与通过iPro2获得的葡萄糖测量值之间存在显着相关性:葡萄糖(FreeStyle Libre Pro)(mg / dl)= 0.86×葡萄糖(iPro2)-3.31(mg / dl),r = 0.914, P <0.01。结论:FreeStyle Libre Pro方便使用,因为它不需要通过指尖葡萄糖测试进行校准,但是我们的结果支持通过常规指尖葡萄糖测试或中心实验室测试确认FreeStyle Libre Pro的测量结果的重要性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号