On the use of photoacoustics to detect red blood cell aggregation

机译:关于使用光声技术检测红细胞聚集

获取原文
获取外文期刊封面目录资料

摘要

The feasibility of detecting red blood cell (RBC) aggregation with photoacoustics (PAs) was investigated theoretically and experimentally using human and porcine RBCs. The theoretical PA signals and spectra generated from such samples were examined for several hematocrit levels and aggregates sizes. The effect of a finite transducer bandwidth on the received PA signal was also examined. The simulation results suggest that the dominant frequency of the PA signals from non-aggregated RBCs decreases towards clinical frequency ranges as the aggregate size increases. The experimentally measured mean spectral power increased by ~6 dB for the largest aggregate compared to the non-aggregated samples. Such results confirm the theoretical predictions and illustrate the potential of using PA imaging for detecting RBC aggregation.
机译:在理论上和实验上,使用人和猪的RBC,研究了用光声(PA)检测红细胞(RBC)聚集的可行性。检查了从此类样品产生的理论PA信号和光谱的几个血细胞比容水平和聚集体大小。还检查了有限的传感器带宽对接收到的PA信号的影响。仿真结果表明,来自非聚集RBC的PA信号的主频率随着聚集大小的增加而朝着临床频率范围减小。与非聚集样本相比,最大聚集体的实验测量平均频谱功率增加了〜6 dB。这些结果证实了理论预测,并说明了使用PA成像检测RBC聚集的潜力。