In this paper, we demonstrate the use of optical coherence tomography/optical microangiography (OCT/OMAG) to image and measure the effects of acute intraocular pressure (IOP) elevation on retinal, choroidal and optic nerve head (ONH) perfusion in the rat eye. In the experiments, IOP was elevated from 10 to 100 mmHg in 10 mmHg increments. At each IOP level, three-dimensional data volumes were captured using an ultrahigh sensitive (UHS) OMAG scanning protocol for 3D volumetric perfusion imaging, followed by repeated B-scans for Doppler OMAG analysis to determine blood flow velocity. Velocity and vessel diameter measurements were used to calculate blood flow in selected retinal blood vessels. Choroidal perfusion was calculated by determining the peripapillary choroidal filling at each pressure level and calculating this as a percentage of area filling at baseline (10 mmHg). ONH blood perfusion was calculated as the percentage of blood flow area over a segmented ONH area to a depth 150 microns posterior to the choroidal opening. We show that volumetric blood flow reconstructions revealed detailed 3D maps, to the capillary level, of the retinal, choroidal and ONH microvasculature, revealing retinal arterioles, capillaries and veins, the choroidal opening and a consistent presence of the central retinal artery inferior to the ONH. While OCT structural images revealed a reversible compression of the ONH and vasculature with elevated IOP, OMAG successfully documented changes in retinal, choroidal and ONH blood perfusion and allowed quantitative measurements of these changes. Starting from 30 mm Hg, retinal blood flow (RBF) diminished linearly with increasing IOP and was nearly extinguished at 100 mm Hg, with full recovery after return of IOP to baseline. Choroidal filling was unaffected until IOP reached 60 mmHg, then decreased to 20% of baseline at IOP 100 mmHg, and normalized when IOP returned to baseline. A reduction in ONH blood perfusion at higher IOP’s was also observed, but shadow from overlying retinal vessels at lower IOP’s limited precise measurements of changes in ONH capillary perfusion compared to baseline. Therefore, OCT/OMAG can be a useful tool to image and measure blood flow in the retina, choroidal and ONH of the rat eye as well as document the effects of elevated IOP on blood flow in these vascular beds.
机译:在本文中,我们演示了使用光学相干断层扫描/光学微血管造影(OCT / OMAG)成像和测量急性眼内压(IOP)升高对大鼠眼视网膜,脉络膜和视神经头(ONH)灌注的影响。在实验中,IOP以10 mmHg的增量从10 mmHg升高到100 mmHg。在每个IOP级别,使用超高灵敏度(UHS)OMAG扫描协议捕获三维数据,以进行3D体积灌注成像,然后重复进行B扫描以进行多普勒OMAG分析以确定血流速度。使用速度和血管直径测量来计算所选视网膜血管中的血流量。通过确定每个压力水平下的乳头状脉络膜脉络膜充盈,并将其计算为基线(10 mmHg)时面积充盈的百分比来计算脉络膜灌注。将ONH血液灌注计算为在分割的ONH区域内血流面积的百分比,直至脉络膜开口后150微米深。我们显示,容积血流重建揭示了视网膜,脉络膜和ONH微脉管系统的毛细血管水平的详细3D映射,揭示了视网膜小动脉,毛细血管和静脉,脉络膜开口以及始终低于ONH的中央视网膜动脉的存在。 OCT结构图像显示,随着IOP升高,ONH和脉管系统可逆压缩,OMAG成功记录了视网膜,脉络膜和ONH血液灌注的变化,并允许对这些变化进行定量测量。从30 mm Hg开始,随着IOP的增加,视网膜血流(RBF)线性减少,并在100 mm Hg时几乎消失,在IOP恢复至基线后完全恢复。脉络膜充盈直到IOP达到60 mmHg才受影响,然后在IOP 100 mmHg时降至基线的20%,并在IOP返回基线时恢复正常。还观察到在较高IOP时ONH血液灌注减少,但是在较低IOP时视网膜上血管覆盖的阴影限制了ONH毛细血管灌注与基线相比变化的精确测量。因此,OCT / OMAG可以是有用的工具,可以对大鼠眼的视网膜,脉络膜和ONH中的血流进行成像和测量,并可以证明IOP升高对这些血管床中血流的影响。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号