首页> 外文期刊>Desalination and water treatment >The effect of UV pre-treatment on biofouling of BWRO membranes: A field study
【24h】

The effect of UV pre-treatment on biofouling of BWRO membranes: A field study

机译:紫外线预处理对BWRO膜生物结垢的影响:现场研究

获取原文
获取原文并翻译 | 示例
           

摘要

The use of biocides, particularly chlorine, in reverse osmosis (RO) desalination is widely practiced despite documented evidence that although biocides may be advantageous in controlling micro-bial counts in the water, in some cases they can actually exacerbate biofouling of the membranes. The adverse effects, associated with widespread biocide use, have spurred the need for finding alternative RO pre-treatment disinfection methods. Ultraviolet (UV) disinfection, and specifically medium pressure ultraviolet (MP-UV) disinfection has been considered a possible alternative and is now gaining recognition as a viable disinfection method applicable to RO desalination; however documentation on the effects of UV pre-treatment on RO membrane biofouling is scarce. This paper reports the findings from a four month field study conducted at a brackish water reverse osmosis (BWRO) desalination plant, treating groundwater, in the north of Israel, in which MP-UV was applied as a pre-treatment disinfection step prior to RO desalination. The plant contains two double stage desalination trains that operate in parallel - one train served as a reference, while in the other an Atlantium HOD™ MP-UV system was installed. Both trains were run in parallel, and for the duration of the study, all normalized performance parameters were collected and microbial counts monitored. At the end of the run previously replaced sacrificial membranes, situated in the front of the first stages, were autopsied and various biofilm analyses were conducted to elucidate cell/extracellular polymeric substances (EPS) content and microbial speciation. The overall results suggest that MP-UV pre-treatment prolonged the train performance, which manifested itself in a lower relative normalized permeate flux decline vs. the train which received water without MP-UV pre-treatment (11% vs. 17%, respectively). Significantly less EPS was found on the RO membrane which received MP-UV treated water. The differences in biofilm thickness and cell density counts (cells/cm~2) between the two membranes were notable, in favor of UV pre-treatment, yet less significant. The MP-UV pre-treatment also had a substantial effect on biofilm community composition; the RO membrane that received MP-UV disinfected water exhibited a biofilm in which the diversity was reduced by 30% and more, and did not contain certain phylogenetic groups that were detected on the RO membrane that received water without MP-UV pre-treatment. It can be concluded that pre-treatment disinfection using MP-UV may be a promising option for combating biofouling of RO membranes and prolonging operation of the trains between cleaning regimes.
机译:尽管有证据表明尽管杀生物剂在控制水中的微生物数量方面可能是有利的,但在某些情况下,它们实际上会加剧膜的生物污染,但在反渗透(RO)海水淡化中使用杀生物剂,尤其是氯,已得到广泛实践。与广泛使用杀生物剂相关的不利影响刺激了寻找替代RO预处理消毒方法的需要。紫外线(UV)消毒,特别是中压紫外线(MP-UV)消毒被认为是一种可能的替代方法,目前已被认可为适用于反渗透淡化的可行消毒方法。然而,关于紫外线预处理对反渗透膜生物污染影响的文献很少。本文报告了在以色列北部的一个半咸水反渗透(BWRO)淡化厂进行的为期四个月的现场研究的结果,该淡化厂用于处理以色列北部的地下水,其中在进行RO之前将MP-UV用作预处理消毒步骤海水淡化。该工厂包含两个并行运行的双级海水淡化列车-一列用作参考,另一列安装了Atlantium HOD™MP-UV系统。两列火车并行运行,在研究期间,收集了所有归一化的性能参数并监测了微生物计数。运行结束后,对位于第一阶段前部的先前更换的牺牲膜进行尸检,并进行各种生物膜分析以阐明细胞/细胞外聚合物质(EPS)的含量和微生物形态。总体结果表明,MP-UV预处理可延长列车性能,这表现为相对于未经过MP-UV预处理的列车,其相对归一化的渗透通量下降幅度较小(分别为11%和17%) )。在接受MP-UV处理的水的RO膜上发现的EPS少得多。两个膜之间的生物膜厚度和细胞密度计数(细胞/ cm〜2)之间的差异是显着的,有利于紫外线预处理,但意义不大。 MP-UV预处理也对生物膜群落组成有重大影响。接受MP-UV消毒水的RO膜表现出生物膜,其多样性降低了30%以上,并且不包含未经MP-UV预处理而接受水的RO膜上检测到的某些系统发育基团。可以得出结论,使用MP-UV进行预处理消毒可能是对抗RO膜的生物污染和延长清洗方案之间列车运行时间的有前途的选择。

著录项

  • 来源
    《Desalination and water treatment》 |2011年第3期|p.151-163|共13页
  • 作者单位

    Atlantium Technologies Ltd. Beit Shemesh, 99100, Israel;

    Department of Plant and Environmental Sciences, The Institute of Life Sciences, The Hebrew University of Jerusalem, Givat Ram, Jerusalem, 91904 Israel;

    Atlantium Technologies Ltd. Beit Shemesh, 99100, Israel;

    Ben Gurion University of the Negev, The Zuckerberg Institute for Water Research, Sede Boqer Campus, Midreshet Ben-Gurion, 84990 Israel;

    Atlantium Technologies Ltd. Beit Shemesh, 99100, Israel;

    Institute for Soil, Water and Environmental Sciences ARO, Volcani Research Center P.O. Box 6, Beit Dagan, 50250 Israel;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    ultraviolet; reverse osmosis; membranes; biofouling; EPS; flux;

    机译:紫外线反渗透;膜生物污染每股收益;通量;