The aim of this study was to investigate an electrochemical process for bulk disinfection of biologically treated sewage. The influence of operating conditions (current density and flow rate) on the electrochemical formation of free chlorine in the sewage was determined. Furthermore, the effect of wastewater-specific parameters on the inactivation of Escherichia coli was studied. The disinfection capacity is primarily influenced by the concentration of electrochemically produced free chlorine. The production rate of free chlorine is independent of the flow rate within the range of 25-125 L h~(-1) . The investigations have also shown that the electrochemical disinfection of E. coli in secondary effluents with BDD electrodes proceeds effectively at an electric charge input of 0.1-0.15 Ah L~(-1) corresponding to an energy expenditure of 2.0-2.6 kWh m~(-3). The electrochemically generated concentration of free chlorine (c = 0.4-0.6 mg L~(-1)) is sufficient for an E. coli reduction of four log levels under the following conditions: after-reaction time of 15-20min, T>6℃, pH<8.5 and DOC<22mgL~(-1). The formation of organic by-products (AOX, THMs) was marginal to moderate. The inorganic by-products chlorate (1.2mg L~(-1)) and perchlorate (18mg L~(-1)) were produced in considerable concentrations.
机译:这项研究的目的是研究一种电化学方法,用于对经过生物处理的污水进行整体消毒。确定了操作条件(电流密度和流速)对污水中游离氯的电化学形成的影响。此外,研究了废水特定参数对大肠杆菌灭活的影响。消毒能力主要受电化学产生的游离氯浓度的影响。游离氯的产生速率与流速在25-125 L h〜(-1)范围内无关。研究还表明,用BDD电极对二次废水中的大肠杆菌进行电化学消毒可在输入电荷为0.1-0.15 Ah L〜(-1)的情况下有效地进行消毒,这对应于2.0-2.6 kWh m〜( -3)。电化学生成的游离氯浓度(c = 0.4-0.6 mg L〜(-1))在以下条件下足以使大肠杆菌减少四个对数水平:反应后时间15-20min,T> 6 ℃,pH <8.5,DOC <22mgL〜(-1)。有机副产物(AOX,THMs)的形成处于边缘到中等程度。无机副产物氯酸盐(1.2mg L〜(-1))和高氯酸盐(18mg L〜(-1))的浓度很高。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号