首页> 外文期刊>Dental materials >Fracture strength of temporary fixed partial dentures:CAD/CAM versus directly fabricated restorations
【24h】

Fracture strength of temporary fixed partial dentures:CAD/CAM versus directly fabricated restorations

机译:临时固定局部义齿的断裂强度:CAD / CAM与直接制作的修复体

获取原文
获取原文并翻译 | 示例
       

摘要

Objectives. This study aimed at investigating the influence of fabrication method, storage condition and material on the fracture strength of temporary 3-unit fixed partial dentures (FPDs). Methods. A CrCo-alloy master model with a 3-unit FPD (abutment teeth 25 and 27) was manufactured. The master model was scanned and the data set transferred to a CAD/CAM unit (Cercon Brain Expert, Degudent, Hanau, Germany). Temporary 3-unit bridges were produced either by milling from pre-fabricated blanks (Trim, Luxatemp AM Plus, Cercon Base PMMA) or by direct fabrication (Trim, Luxatemp AM Plus). 10 FPDs per experimental group were subjected either to water storage at 37 °C for 24 h and 3 months, respectively, or thermocycled (TC, 5000x, 5-55 °C, 1 week). Maximum force at fracture (Fmax) was determined in a 3-point bending test at 200 mm/min. Data was analyzed using parametric statistics (a = 5%). Results. Fmax values ranged from 138.5 to 1115.5 N. FPDs, which were CAD/CAM fabricated, showed a significant higher Fmax compared to the directly fabricated bridges (p<0.05). TC significantly affected Fmax for Luxatemp (p < 0.05) but not for the PMMA based materials (p > 0.05). CAD/CAM milled FPDs made of Luxatemp showed significantly higher Fmax values compared to Trim and Cercon Base PMMA (p<0.05). Significance. CAD/CAM fabricated FPDs exhibit a higher mechanical strength compared to directly fabricated FPDs, when manufactured of the same material. Composite based materials seem to offer clear advantages versus PMMA based materials and should, therefore, be considered for CAD/CAM fabricated temporary restorations.
机译:目标。这项研究旨在调查制作方法,存储条件和材料对临时3单位固定局部义齿(FPD)断裂强度的影响。方法。制造了具有3个单位FPD(基台齿25和27)的CrCo合金主模型。扫描主模型,并将数据集传输到CAD / CAM单元(德国哈瑙Degudent的Cercon Brain Expert)。通过预制板(Trim,Luxatemp AM Plus,Cercon Base PMMA)进行铣削或直接制造(Trim,Luxatemp AM Plus)来生产临时的3单元桥。每个实验组10个FPD分别在37°C下贮水24 h和3个月,或进行热循环(TC,5000x,5-55°C,1周)。在200 mm / min的三点弯曲试验中确定最大断裂力(Fmax)。使用参数统计分析数据(a = 5%)。结果。 Fmax值在138.5到1115.5 N之间。与直接制造的桥相比,CAD / CAM制造的FPD显示出明显更高的Fmax(p <0.05)。 TC显着影响Luxatemp的Fmax(p <0.05),但不影响基于PMMA的材料(p> 0.05)。与Trim和Cercon Base PMMA相比,由Luxatemp制造的CAD / CAM研磨FPD显示出明显更高的Fmax值(p <0.05)。意义。当由相同材料制造时,与直接制造的FPD相比,CAD / CAM制造的FPD表现出更高的机械强度。基于复合材料的材料似乎比基于PMMA的材料具有明显优势,因此,应考虑将其用于CAD / CAM制造的临时修复体。

著录项

  • 来源
    《Dental materials》 |2011年第4期|p.339-347|共9页
  • 作者单位

    Department of Prosthetic Dentistry, Justus-Liebig-University, D-35392 Giessen, Germany;

    Clinic of Operative Dentistry, Periodontology and Preventive Dentistry, Saarland University Hospital, Building 73, D-66421 Homburg,Saar, Germany;

    Department of Prosthetic Dentistry, Justus-Liebig-University, D-35392 Giessen, Germany;

    Clinic of Operative Dentistry, Periodontology and Preventive Dentistry, Saarland University Hospital, Building 73, D-66421 Homburg,Saar, Germany,Department of Prosthetic Dentistry, Justus-Liebig-University, D-35392 Giessen, Germany;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);美国《化学文摘》(CA);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    temporary fixed partial denture; interim restoration; provisional restoration; fracture strength; composites; 3-point bending test; resin; thermocycling; in vitro study;

    机译:临时固定局部义齿;临时修复;临时修复;断裂强度;复合材料;三点弯曲试验;树脂;热循环;体外研究;
  • 入库时间 2022-08-18 03:47:17

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号