首页> 外文期刊>IEEE Transactions on Control Systems Technology >Comments on “A Novel Fault Diagnostics and Prediction Scheme Using a Nonlinear Observer With Artificial Immune System as an Online Approximator”
【24h】

Comments on “A Novel Fault Diagnostics and Prediction Scheme Using a Nonlinear Observer With Artificial Immune System as an Online Approximator”

机译:关于“使用人工免疫系统的非线性观测器作为在线近似器的新型故障诊断和预测方案”的评论

获取原文
获取原文并翻译 | 示例
           

摘要

In this letter, we point out that the asymptotic convergence, claimed in Theorem 2, of the output residual and parameter estimation error after fault occurrence are guaranteed by the performance of the fault diagnosis observer is not quite right. The proof of the asymptotic convergence is contributed by Lemma 1 and negative semidefiniteness of the first difference of Lyapunov candidate function. Here, it is shown that utilizing Lemma 1 yields in some disputed points in the proof of Theorem 2. On the other hand, the proof of Theorem 2 is not mathematically correct. Therefore, the guarantee of the asymptotic convergence mentioned for FD observer in Theorem 2 is not realizable.
机译:在这封信中,我们指出了定理2中所主张的渐近收敛性,即故障诊断观察者的性能不能保证故障发生后的输出残差和参数估计误差。渐近收敛的证明是由引理1和Lyapunov候选函数的第一个差的负半定性引起的。在这里,证明了在定理2的证明中利用引理1产生了一些有争议的观点。另一方面,定理2的证明在数学上是不正确的。因此,定理2中为FD观测器提到的渐近收敛性的保证是无法实现的。