首页> 外文期刊>Construction and Building Materials >Bond strength of hot-dip galvanized hooked bars in high strength concrete structures
【24h】

Bond strength of hot-dip galvanized hooked bars in high strength concrete structures

机译:高强度混凝土结构中热浸镀锌钩杆的粘结强度

获取原文
获取原文并翻译 | 示例
获取外文期刊封面目录资料

摘要

In 2001, a multi-phase research program was started at the American University of Beirut (AUB) to evaluate the effect of steel galvanizing on bond strength of reinforcement in concrete structures. This paper reports on the fourth phase of the program designed to assess the effect of steel galvanizing on bond strength of hooked bars anchored in high strength concrete structures. Twelve specimens, each simulating the rigid connection of two cantilever beams to a column, were tested. The variables included bar size and the confinement mode of the beam bars anchored in the column. Test results indicated that galvanizing caused a consistent reduction in bond strength of hooked bars ranging from 6% to 17% with an average of 13%. This is contrary to the results of the earlier phase of the AUB program which indicated strength concrete structures. Based on analysis of test results of all four phases of the AUB research program, design recommendations insignificant effect of steel galvanizing on bond strength of hooked bars anchored in normal are provided concerning the anchorage length of galvanized reinforcing bars in normal and high strength concrete structures.
机译:2001年,贝鲁特美国大学(AUB)启动了一个多阶段研究计划,以评估镀锌对混凝土结构中钢筋粘结强度的影响。本文报告了该计划的第四阶段,该计划旨在评估镀锌对锚固在高强度混凝土结构中的钩杆粘结强度的影响。测试了十二个样本,每个样本模拟了两个悬臂梁与圆柱的刚性连接。变量包括钢筋尺寸和锚固在柱中的梁钢筋的约束模式。测试结果表明,镀锌导致钩杆的粘结强度持续降低,范围从6%降低到17%,平均降低13%。这与AUB计划早期阶段的结果相反,后者表明了混凝土结构的强度。根据AUB研究计划所有四个阶段的测试结果的分析,就普通和高强度混凝土结构中镀锌钢筋的锚固长度,提供了设计建议,对镀锌钢筋对锚固在正常状态的钩形钢筋的粘结强度影响不大。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号