...
首页> 外文期刊>Computer methods in biomechanics and biomedical engineering >A new method for motion capture of the scapula using an optoelectronic tracking device: a feasibility study
【24h】

A new method for motion capture of the scapula using an optoelectronic tracking device: a feasibility study

机译:一种使用光电跟踪装置捕获肩cap骨的新方法:可行性研究

获取原文
获取原文并翻译 | 示例
           

摘要

Optoelectronic tracking systems are rarely used in 3D studies examining shoulder movements including the scapula. Among the reasons is the important slippage of skin markers with respect to scapula. Methods using electromagnetic tracking devices are validated and frequently applied. Thus, the aim of this study was to develop a new method for in vivo optoelectronic scapular capture dealing with the accepted accuracy issues of validated methods.rnEleven arm positions in three anatomical planes were examined using five subjects in static mode. The method was based on local optimisation, and recalculation procedures were made using a set of five scapular surface markers.rnThe scapular rotations derived from the recalculation-based method yielded RMS errors comparable with the frequently used electromagnetic scapular methods (RMS up to 12.6° for 150° arm elevation). The results indicate that the present method can be used under careful considerations for 3D kinematical studies examining different shoulder movements.
机译:在3D研究中很少使用光电跟踪系统来检查包括肩cap骨在内的肩部运动。原因之一是皮肤标记物相对于肩cap骨的重要滑动。使用电磁跟踪设备的方法已得到验证并经常应用。因此,本研究的目的是开发一种新的体内光电子肩cap骨捕获方法,以解决经验证的方法公认的准确性问题。在五个解剖对象的静态模式下,检查了三个解剖平面中的11个手臂位置。该方法基于局部优化,并使用一组五个肩cap骨表面标记进行重新计算程序.rn基于重新计算方法的肩cap骨旋转产生的RMS误差与常用的电磁肩骨方法相当(RMS高达12.6°手臂仰角为150°)。结果表明,本方法可以在仔细考虑用于检查不同肩膀运动的3D运动学研究中使用。

著录项

  • 来源
  • 作者

    Miroslav Senk; Laurence Cheze;

  • 作者单位

    Universite de Lyon, Laboratoire de Biomecanique et Mecanique des Chocs - UMR_T 9406, Universite Lyon 1 - INRETS, Batiment Omega, 43 Boulevard du 11 Novembre 1918, Villeurbanne F-69622, France Department of Physiotherapy, Faculty of Physical Education and Sports, Charles University, Prague, Czech Republic;

    rnUniversite de Lyon, Laboratoire de Biomecanique et Mecanique des Chocs - UMR_T 9406, Universite Lyon 1 - INRETS, Batiment Omega, 43 Boulevard du 11 Novembre 1918, Villeurbanne F-69622, France;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    shoulder kinematics; scapula tracking; skin marker slippage;

    机译:肩部运动学肩cap骨追踪;皮肤标记滑移;

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号