The effect of stress distribution due to the changes of the distal screw alignment in relation to the Gamma nail and the femoral shaft is thoroughly studied in this paper. Failure of the Gamma nail composite occurs through the cranial aperture of the distal screws and the insertion hole for the lag screw due to nonunion, delayed-union and continued weight-bearing. A three-dimensional finite element model was used to study the fractured femur, the Gamma nail, the lag screw and the distal locking screws. The first and the second distal screws were inserted into the Gamma nail in four different configurations. We found that the stress of the Gamma nail composite was substantially reduced with the two screws configured in the anterior to posterior direction. This alignment can bear greater loading in the more demanding fracture types. In the subtrochanteric fracture or the comminuted fractures at the proximal femur, the optimal alignment of the two distal screws was in the anterior to posterior direction.
机译:本文深入研究了由于远端螺钉排列相对于Gamma钉和股骨干的变化而引起的应力分布的影响。由于不愈合,延迟愈合和持续承重,伽玛钉复合材料的破坏会通过远端螺钉的颅骨孔和方头螺钉的插入孔发生。使用三维有限元模型来研究股骨骨折,Gamma钉,方头钉和远端锁定螺钉。将第一和第二远端螺钉以四种不同的配置插入Gamma钉中。我们发现,使用前后方向上配置的两个螺钉,可大大降低Gamma钉复合材料的应力。在更苛刻的裂缝类型中,这种对准可以承受更大的载荷。在股骨转子下骨折或股骨近端粉碎性骨折中,两个远端螺钉的最佳排列方向为前后方向。