首页> 外文期刊>Bulletin of Materials Science >A new ion-selective electrode based on aluminium tungstate for Fe(III) determination in rock sample, pharmaceutical sample and water sample
【24h】

A new ion-selective electrode based on aluminium tungstate for Fe(III) determination in rock sample, pharmaceutical sample and water sample

机译:一种基于钨酸铝的新型离子选择电极,用于岩石样品,药物样品和水样品中的Fe(III)测定

获取原文
获取原文并翻译 | 示例
           

摘要

An inorganic cation exchanger, aluminum tungstate (AT), has been synthesized by adding 0·1 M sodium tungstate gradually into 0·1 M aluminium nitrate at pH 1·2 with continuous stirring. The ion exchange capacity for Na+ ion and distribution coefficients of various metal ions was determined on the column of aluminium tungstate. The distribution studies of various metal ions showed the selectivity of Fe(III) ions by this cation exchange material. So, a Fe(III) ion-selective membrane electrode was prepared by using this cation exchange material as an electroactive material. The effect of plasticizers viz. dibutyl phthalate (DBP), dioctylphthalate (DOP), di-(butyl) butyl phosphate (DBBP) and tris-(2-ethylhexylphosphate) (TEHP), has also been studied on the performance of membrane sensor. It was observed that the membrane containing the composition AT: PVC: DBP in the ratio 2: 20: 15 displayed a useful analytical response with excellent reproducibility, low detection limit, wide working pH range (1–3·5), quick response time (15 s) and applicability over a wide concentration range of Fe(III) ions from 1 × 10−7 M to 1 × 10−1 M with a slope of 20 ± 1 mV per decade. The selectivity coefficients were determined by the mixed solution method and revealed that the electrode was selective for Fe(III) ions in the presence of interfering ions. The electrode was used for atleast 5 months without any considerable divergence in response characteristics. The constructed sensor was used as indicator electrode in the potentiometric titration of Fe(III) ions against EDTA and Fe(III) determination in rock sample, pharmaceutical sample and water sample. The results are found to be in good agreement with those obtained by using conventional methods.
机译:通过在连续搅拌下将0·1 M钨酸钠逐渐添加到pH 1·2的0·1 M硝酸铝中,合成了一种无机阳离子交换剂钨酸铝(AT)。在钨酸铝柱上测定Na + 离子的离子交换容量和各种金属离子的分布系数。各种金属离子的分布研究表明,该阳离子交换材料对Fe(III)离子具有选择性。因此,通过使用该阳离子交换材料作为电活性材料来制备Fe(III)离子选择性膜电极。增塑剂的作用。还对膜传感器的性能进行了研究,包括邻苯二甲酸二丁酯(DBP),邻苯二甲酸二辛酯(DOP),磷酸二(丁)丁酯(DBBP)和三-(2-乙基己基磷酸酯)(TEHP)。已观察到,含有比例为2:20:15的AT:PVC:DBP的膜表现出有用的分析响应,具有出色的重现性,低检测限,宽的工作pH范围(1-3·5),响应时间短(15 s)且适用于从1×10 −7 M到1×10 −1 M的宽浓度范围的Fe(III)离子,斜率为20每十年±1 mV。通过混合溶液法确定选择性系数,结果表明电极在存在干扰离子的情况下对Fe(III)离子具有选择性。电极使用至少5个月,反应特性没有明显差异。所构建的传感器用作针对岩石样品,药物样品和水样品中的EDTA电位滴定法测定Fe(III)离子的指示电极和Fe(III)的指示电极。发现结果与使用常规方法获得的结果非常一致。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号