Operating room (OR) is an indispensable department in a hospital, while its ventilation system is an important engineering solution to ensure safety for surgical procedures. Suitable ventilation system in the OR should be defined as using the minimum energy consumption and lifecycle cost to meet both the requirements of clean air for safe surgeries and comfort for occupants. Therefore, this study aims to develop a flexible evaluation framework on the suitability evaluation for ventilation system performance in ORs from a holistic view instead of one aspect only. To achieve the objective, we adopted analytic hierarchy process (AHP) and fuzzy comprehensive evaluation (FCE) methods and conducted suitability evaluation for two ORs with laminar airflow (LAF) and mixing ventilation (MV) system in St. Olavs Hospital, Norway. The evaluation includes seven indexes under three main aspects: ventilation effectiveness, energy consumption and users? satisfaction. The comprehensive evaluation results are obtained through site measurements during mock surgeries, data collection and calculation as well as the questionnaire survey. Due to the unsatisfactory performance in energy consumption and thermal comfort indexes, the evaluation result of the suitability performance of the case OR with MV system was ?unsuitable? while the one with LAF system was ?suitable?, which reflects the situation that the energy consumption and thermal environment are sacrificed, although a clean and safe operation environment is guaranteed. The evaluation can provide basis for the commissioning of the ventilation system in the ORs of St. Olavs Hospital and provoke thinking of the ventilation system design and operation in the future.
机译:手术室(或)是一家医院不可或缺的部门,而其通风系统是一种重要的工程解决方案,以确保外科手术的安全性。合适的通风系统或者应该定义为使用最小能耗和生命周期成本,以满足清洁空气的要求,以便安全手术和居住者的舒适。因此,本研究旨在开发一种灵活的评估框架,适用于来自整体视图而不是一个方面的通风系统性能的适用性评估。为实现目标,我们采用了分析层次处理(AHP)和模糊综合评估(FCE)方法,对挪威圣奥拉夫医院的层流(LAF)和混合通风(MV)系统进行了适合性评价。评估包括三个主要方面的七个指标:通风效率,能源消耗和用户?满意。通过模拟手术,数据收集和计算以及调查问卷调查,通过现场测量获得综合评估结果。由于能耗和热舒适指数的性能不令人满意,壳体或MV系统的适当性能的评价结果​​是不合适的?虽然具有LAF系统的人是合适的?,这反映了所牺牲能量消耗和热环境的情况,尽管保证了清洁和安全的操作环境。评估可以为圣奥拉夫斯医院或者在奥斯医院或者挑起未来通风系统设计和操作的思考的依据。

著录项

  • 来源
    《Building and Environment》 |2021年第5期|107677.1-107677.15|共15页
  • 作者单位

    Tianjin Univ Sch Civil Engn Tianjin Peoples R China|Norwegian Univ Sci & Technol Dept Energy & Proc Engn Trondheim Norway|Tianjin Univ Tianjin Key Lab Built Environm & Energy Applicat Tianjin Peoples R China;

    Norwegian Univ Sci & Technol Dept Energy & Proc Engn Trondheim Norway;

    Norwegian Univ Sci & Technol Dept Energy & Proc Engn Trondheim Norway;

    Tianjin Univ Sch Civil Engn Tianjin Peoples R China|Tianjin Univ Sch Environm Sci & Engn Tianjin Peoples R China|Tianjin Univ Tianjin Key Lab Built Environm & Energy Applicat Tianjin Peoples R China;

    St Olavs Hosp Operating Room Trondheim Norway;

    St Olavs Hosp Operating Room Trondheim Norway;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Air distribution strategy; Operating room; Suitability; Evaluation;

    机译:空气分配策略;手术室;适用性;评估;
  • 入库时间 2022-08-18 23:33:45

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号