首页> 外文期刊>Building and Environment >Thermal comfort in Supermarket's refrigerated areas: An integrated survey in central Italy
【24h】

Thermal comfort in Supermarket's refrigerated areas: An integrated survey in central Italy

机译:超市冷藏区的热舒适性:意大利中部的一项综合调查

获取原文
获取原文并翻译 | 示例

摘要

Thermal comfort conditions in supermarkets have been barely investigated in the past and only few meaningful studies have been carried out involving customers and staff. In this paper, the results of an integrated investigation on thermal conditions of customers and staff in refrigerated areas of four supermarkets in Central Italy are presented and discussed. Microclimatic surveys demonstrated that thermal comfort conditions for staff were generally consistent with ISO 7730 requirements. To the contrary, considering worn clothes, the thermal sensation predicted for customers was generally turned towards the cold both in autumn and summer with PMV values often below -2.The analysis of the local microclimatic parameters revealed low floor temperatures and a meaningful cold air stratification characterized by air temperature vertical differences measured between head and ankles up to 8-9 degrees C in case of open cabinets. In summer, due to the lower air temperature values (compared to the outdoor) combined with the usual low thermal insulation of clothes, the thermal environment is cold and the IREQ model revealed dangerous conditions for customers in three of the investigated areas with DLE (Duration Limit of Exposure) of about 40 min. In autumn, DLEs largely exceeded 1 h. Results of the subjective investigation carried out in two sales points for 35 customers were consistent with the objective survey and revealed higher percentages of dissatisfied in case of women. Finally, local discomfort due to cold feet effect seemed to be more consistent for women due to the low clothing distribution in lower parts of the body.
机译:过去,几乎没有对超市的热舒适条件进行调查,只有很少的有意义的研究涉及顾客和员工。本文介绍并讨论了对意大利中部四个超市的冷藏区域中的客户和员工的热状况进行的综合调查结果。微气候调查表明,员工的热舒适条件通常符合ISO 7730要求。相反,考虑到穿旧衣服,在秋季和夏季,为客户预测的热感觉通常转向寒冷,PMV值通常低于-2。对当地微气候参数的分析表明,地板温度低且有意义的冷空气分层其特征是,在打开橱柜的情况下,在头和脚踝之间测量的空气温度垂直差异最高可达8-9摄氏度。在夏季,由于较低的空气温度值(与室外相比)以及通常较低的衣服隔热性能,热环境寒冷,IREQ模型对三个调查区域的DLE(持续时间)的客户显示了危险情况暴露极限)约40分钟。在秋天,DLE大大超过了1小时。在两个销售点针对35个客户进行的主观调查结果与客观调查一致,结果表明,女性不满意的比例更高。最后,由于脚下部的衣服分布少,女性因冷脚效应引起的局部不适似乎更为一致。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号