首页> 外文期刊>Building and Environment >Radiant heating utilizing conductive concrete tiles
【24h】

Radiant heating utilizing conductive concrete tiles

机译:利用导电混凝土瓦进行辐射加热

获取原文
获取原文并翻译 | 示例
       

摘要

Conductive concrete tiles of thickness 20-mm were subjected to electrical Joule heating tests. The average temperature increased by 51.62 K in 60 min under 36-V AC (alternating current) power. These tiles were subsequently utilized to build an indoor radiant heating system. Electrical heating tests under different conditions in a room, with the window open or closed, were performed. The results show that the floor tiles are effective for radiant heating. The temperature at the center of the room increased by 4.5 K in approximately 10 min. The energy consumption in 24 h is 0.775 kW-h/m(2) in a thermally insulated room, corresponding to an average power density of 32 W/m(2). This energy consumption is lower than that of typical radiant floor systems with embedded heating cables. A computer model of the room with the heating system is developed to simulate the radiant heating process. The numerical results compare favorably with the test data.
机译:对厚度为20毫米的导电混凝土瓦进行电焦耳加热测试。在36V AC(交流)功率下,平均温度在60分钟内增加了51.62K。这些瓷砖随后被用来建造室内辐射供暖系统。在窗户打开或关闭的情况下,在室内不同条件下进行电加热测试。结果表明,地砖对辐射采暖有效。房间中央的温度在大约10分钟内增加了4.5K。在隔热房间中,24小时内的能耗为0.775 kW-h / m(2),对应于32 W / m(2)的平均功率密度。该能耗低于具有嵌入式加热电缆的典型辐射地板系统的能耗。开发了带有加热系统的房间的计算机模型,以模拟辐射加热过程。数值结果与测试数据相吻合。