首页> 外文期刊>Biorheology >A full-range, multi-variable, CFD-based methodology to identify abnormal near-wall hemodynamics in a stented coronary artery
【24h】

A full-range, multi-variable, CFD-based methodology to identify abnormal near-wall hemodynamics in a stented coronary artery

机译:一种基于CFD的全方位,多变量方法,可识别带支架的冠状动脉中异常的近壁血流动力学

获取原文
获取原文并翻译 | 示例
       

摘要

The benefit of coronary stent implantation is reduced by excessive intimal hyperplasia which re-narrows the artery and the prevention of which is still a primary concern for clinicians. Abnormal hemodynamics create non-physiological viscous stress on the artery wall, one of the root causes of intimal hyperplasia following stent implantation. A methodology to comprehensively evaluate the viscous stress on the artery wall following stent implantation would be useful to evaluate a stent's hemodynamic performance.rnThe proposed methodology employs 3D computational fluid dynamics, the variables wall shear stress (WSS), WSS gradient (WSSG), WSS angle gradient (WSSAG) and a statistical analysis to evaluate the viscous stress. The methodology is demonstrated and compared to a commonly used "threshold technique" for evaluating a stent's hemodynamic performance.rnIt is demonstrated that the threshold technique is not adequate to fully analyse the viscous stress on the artery wall and can even be misleading. Furthermore, all three of the aforementioned variables should be considered as each provides a different perspective on the abnormalities that can arise in the arterial viscous stress.rnThe hemodynamic performance of a stent can be assessed more comprehensively than with previously used methods by examining the arterial viscous stresses using the proposed methodology.
机译:过度的内膜增生会缩小狭窄的冠状动脉,从而降低冠状动脉支架植入术的益处,而预防仍然是临床医生最关注的问题。异常的血流动力学在动脉壁上产生非生理性的粘性应力,这是支架植入后内膜增生的根本原因之一。一种全面评估支架植入后动脉壁粘滞应力的方法将有助于评估支架的血液动力学性能。建议的方法采用3D计算流体动力学,变量壁切应力(WSS),WSS梯度(WSSG),WSS角度梯度(WSSAG)和统计分析来评估粘性应力。演示了该方法,并将其与用于评估支架的血液动力学性能的常用“阈值技术”进行比较。rn证明了阈值技术不足以完全分析动脉壁上的粘性应力,甚至可能会产生误导。此外,应该考虑上述三个变量,因为每个变量都对动脉黏性应激可能出现的异常提供了不同的观点.rnn与以前使用的方法相比,可以通过检查动脉黏性来更全面地评估支架的血液动力学性能强调使用建议的方法。

著录项

  • 来源
    《Biorheology》 |2010年第2期|P.117-132|共16页
  • 作者单位

    Department of Mechanical Engineering, Dublin Institute of Technology, Dublin, Ireland;

    Department of Mechanical Engineering, Dublin Institute of Technology, Dublin, Ireland;

  • 收录信息 美国《科学引文索引》(SCI);美国《化学文摘》(CA);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    stent; intimal hyperplasia; viscous stress; statistical analysis;

    机译:支架内膜增生粘性压力统计分析;