首页> 外文期刊>Bioprocess and Biosystems Engineering >Air-lift internal loop biofilm reactor for realized simultaneous nitrification and denitrification
【24h】

Air-lift internal loop biofilm reactor for realized simultaneous nitrification and denitrification

机译:气升式内环生物膜反应器,实现同时硝化和反硝化

获取原文
获取原文并翻译 | 示例
           

摘要

Simultaneous nitrification and denitrification (SND) was realized by means of a novel air-lift internal loop biofilm reactor, in which aeration was set in middle of the reactor. During operation, the aeration was adjusted to get appropriate dissolve oxygen (DO) in bulk solution and let aerobic and anoxic zone coexist in one reactor. When aeration was at 0.6 and 0.2 L/min, corresponding to DO of 5.8 and 2.5 mg/L in bulk solution, ammonia nitrogen removal percentage reached about 80 and 90 %, but total nitrogen removal percentage was lower than 25 %. While the aeration was reduced to 0.1 L/min, aerobic and anoxic zones existed simultaneously in one reactor to get 75 % of ammonia nitrogen and 50 % of total nitrogen removal percentage. Biofilms were, respectively, taken from aerobic and anoxic zone to verify their function of nitrification and denitrification in two flasks, in which ammonia nitrogen was transferred into nitrate completely by aerobic biofilm, and nitrate was removed more than 80 % by anoxic biofilm. Microelectrode was used to measure the DO distribution inside biofilms in anoxic zone corresponding to different aerations. When aeration was at 0.6 and 0.2 L/min, DO inside biofilm was more than 1.5 mg/L, but the DO inside biofilm decreased to anoxic status with depth of biofilm increasing corresponding to aeration of 0.1 L/min. The experimental results indicated that SND could be realized because of simultaneous existence of aerobic and anoxic biofilms in one reactor.
机译:通过新型气提内环生物膜反应器实现了同时硝化和反硝化(SND),其中在反应器的中间设置了曝气。在操作过程中,调节通气量以获得适当的溶解氧(DO)在本体溶液中,并使好氧和缺氧区域共存于一个反应器中。当通气量为0.6和0.2 L / min时(对应于散装溶液中的DO分别为5.8和2.5 mg / L),氨氮去除率达到约80和90%,但总氮去除率低于25%。当通气量降低至0.1 L / min时,一个反应器中同时存在好氧和缺氧区域,从而获得75%的氨氮和50%的总氮去除率。分别从需氧区和缺氧区获取生物膜,以验证其在两个烧瓶中的硝化和反硝化功能,其中好氧生物膜将氨氮完全转移到硝酸盐中,而缺氧生物膜将硝酸盐去除率超过80%。使用微电极来测量缺氧区域中对应于不同曝气的生物膜内部的DO分布。当通气量分别为0.6和0.2 L / min时,生物膜内部的DO大于1.5 mg / L,但生物膜内部的DO降至缺氧状态,而生物膜的深度增加,对应的通气量为0.1 L / min。实验结果表明,由于在一个反应​​器中同时存在好氧和缺氧生物膜,因此可以实现SND。

著录项

  • 来源
    《Bioprocess and Biosystems Engineering》 |2013年第5期|597-602|共6页
  • 作者单位

    Department of Environmental Engineering, Shanghai Normal University, Shanghai 200234, People's Republic of China;

    Department of Environmental Engineering, Shanghai Normal University, Shanghai 200234, People's Republic of China;

    Department of Environmental Engineering, Shanghai Normal University, Shanghai 200234, People's Republic of China;

    Department of Environmental Engineering, Shanghai Normal University, Shanghai 200234, People's Republic of China;

    Zhejiang Provincial Key Laboratory of Water Science and Technology, Department of Environmental Technology and Ecology, Yangtze Delta Region Institute of Tsinghua University, Zhejiang, Jiaxing 314006, People's Republic of China;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    biofilm; reactor; simultaneous nitrification and denitrification; microelectrode;