首页> 外文期刊>Biomedical Engineering, IEEE Transactions on >PTT Variability for Discrimination of Sleep Apnea Related Decreases in the Amplitude Fluctuations of PPG Signal in Children
【24h】

PTT Variability for Discrimination of Sleep Apnea Related Decreases in the Amplitude Fluctuations of PPG Signal in Children

机译:区分儿童PPG信号幅度波动的睡眠呼吸暂停相关PTT变异性

获取原文
获取原文并翻译 | 示例
           

摘要

In this paper, an analysis of pulse transit time variability (PTTV) during decreases in the amplitude fluctuations of pulse photoplethysmography signal (PPG) (DAP) events for obstructive sleep apnea syndrome (OSAS) screening is presented. The temporal evolution of time–frequency PTTV parameters during DAP was analyzed. The results show an increase in the sympathetic activity index low-frequency component (LF) during DAP for PTTV (85%) significantly higher than for heart rate variability (HRV) (33%), ( $pu0003C; ,$10$^{-13}$). However, decreases in parasympathetic activity produce lower decrements in high-frequency component (HF) indexes for PTTV (18%) than for HRV (22%). Thus, PTTV reflects sympathetic changes more clearly than HRV. A clinical study was carried out. DAP events were classified as apneic or nonapneic using a linear discriminant analysis from the PTTV indexes. The ratio of DAP events per hour $r_{{rm DAP}}$, the ratio after filtering based on HRV indexes $r^{{rm HRV}}_{{rm DAP}}$, or on PTTV indexes $r^{{rm PTTV}}_{{rm DAP}}$, were computed. The results show an accuracy of 75% for $r^{{rm PTTV}}_{{rm DAP}}$ (14% increase with respect to $r_{{rm DAP}}$ and 5% increase with respect to $r^{{rm HRV}}_{{rm DAP}}$), a sensitivity of 81.8%, and a specificity of 73.9% when classifying 1-h polysomnographic excerpts as OSAS or normal. These res-nults suggest that the combination of DAP and PTTV could be better alternative for sleep apnea screening using PPG with the added benefit of its low cost and simplicity.
机译:本文分析了阻塞性睡眠呼吸暂停综合症(OSAS)筛查中脉冲光体积描记器信号(PPG)(DAP)事件幅度波动减小期间的脉冲渡越时间可变性(PTTV)。分析了DAP期间时频PTTV参数的时间演变。结果显示,PTAP的DAP期间交感活动指数低频分量(LF)的增加(85%)明显高于心率变异性(HRV)的增加(33%),($ pu0003C; $ 10 $ ^ {- 13} $)。但是,副交感神经活动的减少使PTTV的高频分量(HF)指数下降(18%),低于HRV(22%)。因此,PTTV比HRV更清楚地反映了同情变化。进行了临床研究。根据PTTV指标的线性判别分析,DAP事件被分类为呼吸暂停或非呼吸暂停。每小时DAP事件的比率$ r _ {{rm DAP}} $,基于HRV索引$ r ^ {{rm HRV}} _ {{rm DAP}} $或PTTV索引$ r ^进行过滤后的比率计算了{{rm PTTV}} _ {{rm DAP}} $。结果显示$ r ^ {{rm PTTV}} _ {{rm DAP}} $的准确度为75%(与$ r _ {{rm DAP}} $相比增加了14%,与$$相比增加了5%。 r ^ {{rm HRV}} _ {{rm DAP}} $),将1-h多导睡眠图摘录归类为OSAS或正常时,灵敏度为81.8%,特异性为73.9%。这些结果表明,DAP和PTTV的组合可能是使用PPG进行睡眠呼吸暂停筛查的更好替代方法,并具有成本低廉和操作简便的优点。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号