首页> 外文期刊>Australasian physical & engineering sciences in medicine >A comprehensive dose assessment of irradiated hand by iridium-192 source in industrial radiography
【24h】

A comprehensive dose assessment of irradiated hand by iridium-192 source in industrial radiography

机译:铱192源在工业射线照相中对手照射的剂量的综合评估

获取原文
获取原文并翻译 | 示例
           

摘要

Among the various incidents in industrial radiography, inadvertent handling of sources by hands is one of the most frequent incidents in which some parts of the hands may be locally exposed to high doses. An accurate assessment of extremity dose assists medical doctors in selecting appropriate treatments, preventing the injury expansion in the region. In this study, a phantom was designed to simulate a fisted hand of a radiographer when the worker holds a radioactive source in their hands. The local doses were measured using implanted TLDs in the phantom at different distances from a source. Furthermore, skin dose distribution was measured by Gaf-chromic films in the palm region of the phantom. The reliability of the measurements has been studied via analytical as well as Monte-Carlo simulation methods. The results showed that the new phantom design can be used reliably in extremity dose assessments, particularly at the points next to the source.
机译:在工业射线照相中的各种事件中,用手不慎操作放射源是最常见的事件之一,在这种事件中,手的某些部分可能会局部暴露于高剂量下。对四肢剂量的准确评估有助于医生选择适当的治疗方法,以防止该部位的损伤扩大。在这项研究中,设计了一个幻影模型来模拟当工人手中拿着放射源时放射线照相者的拳头。使用假体中植入的TLD在距光源不同距离处测量局部剂量。此外,通过幻影的掌区域中的Gaf变色膜来测量皮肤剂量分布。测量的可靠性已通过分析以及蒙特卡洛模拟方法进行了研究。结果表明,新的体模设计可以可靠地用于肢体剂量评估,尤其是在源头附近的点。