...
首页> 外文期刊>Atmospheric environment >Evaluation Of Ozone Measurements From A Tethered Balloon-sampling Platform At South Pole Station In December 2003
【24h】

Evaluation Of Ozone Measurements From A Tethered Balloon-sampling Platform At South Pole Station In December 2003

机译:2003年12月在南极站的系留气球采样平台进行的臭氧测量评估

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

Vertical boundary-layer ozone profiles were measured from a tethered balloon platform during the 2003 Antarctic Tropospheric Chemistry Investigation (ANTCI) at South Pole Station, Antarctica. Electrochemical concentration cell (ECC) ozonesondes were used in obtaining 128 ascent and descent profile measurements to about 500 m height during 13-30 December 2003. Various data checks and intercomparisons were done to confirm the accuracy of the ozonesondes. The ozonesondes compared well to a surface ozone ultra-violet (UV) absorption monitor located next to the tether balloon site. During the 18-day period, ozonesonde measurement checks at the surface averaged 0.2±1.0 ppbv higher than the continuous ozone measurements under ambient concentrations ranging from 18 to 51ppbv. This agreement was also consistent when compared to the nearby NOAA UV-monitor sampling at 17 m above ground level during well-mixed conditions near the surface. In addition to the single ECC sonde profiles, five dual ECC ozonesondes were run on the tether platform. Four release balloon-borne ozonesondes were also launched during the project. Under very sharp ozone gradient events, the release ozonesonde (with a rise rate of ~4-6 m s~(-1)) passed through the gradient layer too quickly to capture the detail as measured by the controlled tethersonde at ~0.3 m s~(-1) ascent/descent rate. Another method of ozone profiling was also done utilizing the UV monitor at the tether site and a 135-m-long Teflon sampling line with a sampling inlet mounted to and raised with the tethered balloon. The ECC ozonesonde averaged about 0.7 + 0.8 ppbv lower than the long-line sampling method from eight profiles.
机译:垂直边界层臭氧剖面是在2003年南极对流层南极站的南极对流层化学调查(ANTCI)期间从系留气球平台测得的。在2003年12月13日至30日期间,使用电化学浓缩池(ECC)臭氧探空仪获得了128处上升和下降剖面的测量值,高度约为500 m。进行了各种数据检查和比较,以确认臭氧探空仪的准确性。臭氧探空仪与位于系留气球位置附近的表面臭氧紫外线(UV)吸收监测仪进行了很好的比较。在18天的时间内,在环境浓度为18至51ppbv的情况下,表面的臭氧探空仪测量检查平均要比连续进行的臭氧测量高0.2±1.0 ppbv。在地面附近充分混合的条件下,与附近的NOAA紫外线监测器在高于地面的17 m处进行采样相比,该协议也是一致的。除了单个ECC探空仪剖面图外,在系绳平台上还运行了五个双ECC臭氧探空仪。在该项目期间,还发射了四枚释放气球的臭氧探空仪。在非常陡峭的臭氧梯度事件下,释放的臭氧探空仪(上升速率约为4-6 ms〜(-1))过快地通过了梯度层,无法捕获受控的系绳探空仪在〜0.3 ms〜( -1)上升/下降速度。臭氧分布的另一种方法是利用系留点处的紫外线监测器和一条135米长的特富龙采样线,将采样入口安装在系留气球上并随其抬高来完成。八种剖面的ECC臭氧探空仪平均比长线采样法低约0.7 + 0.8 ppbv。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号