首页> 外文期刊>Atmospheric environment >Performance evaluation of twelve low-cost PM_(2.5) sensors at an ambient air monitoring site
【24h】

Performance evaluation of twelve low-cost PM_(2.5) sensors at an ambient air monitoring site

机译:在环境空气监测网站上的12个低成本PM_(2.5)传感器的性能评估

获取原文
获取原文并翻译 | 示例
           

摘要

A variety of low-cost sensors are now available on the consumer market for measuring air pollutants. The use of these low-cost sensors for ambient air monitoring applications is increasing and includes fence-line or near-source monitoring, community monitoring, emergency response, hot-spot identification, mobile monitoring, epidemiological studies, and supplemental monitoring to improve the spatial-temporal resolution of current monitoring networks. Evaluating and understanding the performance of these devices is necessary to properly interpret the results and reduce confusion when low-cost sensor measurements are not in agreement with measurements from regulatory-grade instrumentation. Systematic and comprehensive field and laboratory studies comparing low-cost sensors with regulatory-grade instrumentation are necessary to characterize sensor performance. This paper presents the results of 12 particulate matter (PM) sensors measurement of PM2.5 (particles with aerodynamic diameter less than 2.5 mu m) tested under ambient conditions against a federally equivalent method (FEM) instrument at an ambient air monitoring station in Riverside, CA spanning over a 3-year period from 02/05/15 to 03/27/18. Sensors were evaluated in triplicate with a typical time duration of 8-week. Performance evaluation results found 6 of the 12 sensor triplicates with average R-2 values = 0.70 for PM2.5 concentrations less than 50 mu g/m(3). Within this subset, the Mean Absolute Error (MAE) ranged from 4.4 to 7.0 mu g/m(3) indicating the need for caution when interpreting data from these sensors. Additional analysis revealed that the impact of relative humidity on sensor performance varied between models with several models exhibiting increased bias error with increasing humidity. Results indicate that a number of these sensors have potential as useful tools for characterizing PM2.5 levels in ambient environments when data is interpreted and understood correctly with regard to existing ambient air quality networks. The performance evaluation results are specific for Riverside, CA under non-repeatable ambient weather conditions and particle properties with the expectation that performance evaluation testing at other locations with different particle properties and weather conditions would yield similar but non-identical results.
机译:现在可以在消费市场上提供各种低成本传感器,用于测量空气污染物。使用这些低成本传感器进行环境空气监测应用正在增加,包括围栏线或近源监测,社区监测,应急,热点识别,移动监测,流行病学研究以及补充监测,以改善空间 - 目前监控网络的分辨率。评估和理解这些设备的性能是必要的,以便在低成本传感器测量与来自监管级仪器的测量结果不一致时正确解释结果并减少混淆。系统和综合的现场和实验室研究比较具有监管级仪器的低成本传感器,是传感器性能所必需的。本文介绍了12种颗粒物质(PM)传感器的结果测量PM2.5(颗粒的空气动力直径小于2.5 mu m),在河滨环境空气监测站的联邦等效方法(FEM)仪器上测试,加利福尼亚州跨越3年,从02/05/15/15点到03/27/18。传感器以三份评估,典型时间持续时间为8周。 PM2.5浓度小于50μg/ m(3)的PM2.5浓度的平均R-2值,平均R-2值的6个传感器三份酸盐的效果评价结果。在该子集中,平均绝对误差(MAE)的范围为4.4至7.0μg/ m(3),表示在从这些传感器中解释数据时需要小心。额外的分析表明,相对湿度对传感器性能的影响在模型之间变化,其中若干模型具有增加的偏差误差随着湿度的增加。结果表明,当在现有的环境空气质量网络中正确地理解和理解时,许多这些传感器具有用于在环境环境中表征PM2.5水平的有用工具。性能评估结果对于河沿,CA在不可重复的环境天气条件下,颗粒性能,期望在其他具有不同颗粒性能和天气条件的其他地点进行性能评估测试将产生类似但非相同的结果。

著录项

  • 来源
    《Atmospheric environment》 |2019年第11期|116946.1-116946.10|共10页
  • 作者单位

    AQ SPEC South Coast Air Qual Management Dist Diamond Bar CA 91765 USA|Univ Calif Riverside Dept Chem & Environm Engn Riverside CA 92521 USA|Univ Calif Riverside Bourns Coll Engn Ctr Environm Res & Technol CE CERT Riverside CA 92507 USA;

    AQ SPEC South Coast Air Qual Management Dist Diamond Bar CA 91765 USA;

    AQ SPEC South Coast Air Qual Management Dist Diamond Bar CA 91765 USA;

    AQ SPEC South Coast Air Qual Management Dist Diamond Bar CA 91765 USA;

    AQ SPEC South Coast Air Qual Management Dist Diamond Bar CA 91765 USA;

    Univ Calif Riverside Dept Chem & Environm Engn Riverside CA 92521 USA|Univ Calif Riverside Bourns Coll Engn Ctr Environm Res & Technol CE CERT Riverside CA 92507 USA;

    AQ SPEC South Coast Air Qual Management Dist Diamond Bar CA 91765 USA;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Air quality; Fine particulate matter; Low-cost sensors; Optical particle counter; Performance evaluation;

    机译:空气质量;细颗粒物质;低成本传感器;光学粒子计数器;性能评估;

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号