The objective of this field investigation was to compare the impacts on thermal comfort due to vertical location of return air inlets in a residential forced-air system operating in the cooling mode. Design guidelines for forced-air cooling systems recommend placing return air inlet locations above the occupied zone in order to improve circulation of stagnant air and reduce thermal stratification. A companion study of the heating mode is under way. Results from the research will be used to recommend optimal return air inlet locations for year-round performance. An energy-efficient three-story house in Pittsburgh, Pennsylvania, was used as the test site. A single HVAC system, zoned by floor, was operated at a constant setpoint temperature of 72℉ (22.2℃) throughout the investigation. The vertical locations of return air inlets were modified using temporary cardboard ductwork to create two distinct cases for the investigation—one with high returns and one with low returns. Two central data acquisition systems were used to measure system parameters and multiple space temperatures throughout the house on a minute-by-minute basis. The room air temperatures were compared to the requirements ofASHRAE Standard 55 (ASHRAE 2004b) for thermal comfort and recommendations ofACCA Manual D (1995) for uniform temperatures between rooms. Room air temperature stratification for all rooms and all hours was found to be well within ASHRAE guidelines. Although pressure imbalances between spaces were not the focus of the investigation, they appear to have been the driving force of air leakage at zone temperature sensor locations, contributing to room-to-room temperature differences that exceeded ACCA guidelines. Evaluation of the data leads to the conclusion that high return air inlets help reduce stratification in spaces with floor diffusers. However, vertical location of return air inlets appeared to have no impact on cooling performance in spaces with ceiling supply air outlets.
机译:这项现场调查的目的是比较在制冷模式下运行的住宅强制通风系统中,由于回风口的垂直位置对热舒适性的影响。强制空气冷却系统的设计指南建议将回风入口位置放置在占用区域上方,以改善停滞空气的循环并减少热分层。正在进行伴热模式的研究。研究结果将用于推荐最佳回风口位置,以实现全年性能。测试地点是宾夕法尼亚州匹兹堡的一栋节能三层房屋。在整个研究过程中,按地板划分的单个HVAC系统在恒定设定温度722.2(22.2℃)下运行。使用临时纸板管道修改了回风口的垂直位置,以创建两个不同的调查案例–一个回风率高而另一个回风率低。两个中央数据采集系统被用来在每分钟的基础上测量整个房屋的系统参数和多个空间温度。将房间的空气温度与ASHRAE标准55(ASHRAE 2004b)的热舒适性要求和ACCA手册D(1995)关于房间之间的均匀温度的建议进行了比较。发现所有房间和所有时间的房间空气温度分层均符合ASHRAE指南。尽管空间之间的压力不平衡不是研究的重点,但它们似乎是区域温度传感器位置漏气的驱动力,造成了房间间温度差异超过ACCA准则。数据评估得出的结论是,高回风口有助于减少带有地板扩散器的空间内的分层。但是,回风口的垂直位置似乎对带有天花板送风口的空间的冷却性能没有影响。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号