首页> 外文期刊>ASHRAE Transactions >An Analysis of Photovoltaic Performance on Fire Station Buildings in London
【24h】

An Analysis of Photovoltaic Performance on Fire Station Buildings in London

机译:伦敦消防局建筑物的光伏性能分析

获取原文
获取原文并翻译 | 示例

摘要

This paper presents the performance and financial viability of photovoltaic (PV) installations that have been retrofitted to 8 operating fire stations in London.The study analyzes the theoretical performance of each installation using different methodologies, and compares the actual generation yields against the original modeled data by the design consultants. Performance was evaluated with respect to local conditions for each installation such as orientation, tilt angle and shading. Modeling was carried out using approved industry techniques and software packages to investigate the effects of repositioning and upgrading to more efficient panels to ascertain if better solutions could have been implemented.The analysis has shown that the energy generation was generally in keeping with original predictions of the design consultants, providing some confidence in performance forecasting for this technology. A whole life (installation to decommissioning) net present value (NPV) and Internal Rate of Return (IRR) analysis of the PV installations was conducted, including future inverter replacement and re-roofing costs. This revealed that due to a larger than expected capital outlay (particularly for the inverter replacement), the systems did not produce a commercially attractive return on investment.The study also investigated the effect of applying the UK Feed in Tariff (FiT) -for which these systems were not originally eligible — which showed that a simple payback could be achieved within the 25 year system lifetime. The FiT therefore offsets some of the risk associated with roof mounted PV systems.The conclusion of the study is that the current PV installations on eight of the London Fire Brigade stations cannot be considered a viable financial investment without the use of a suitable subsidy, and even this does not provide a substantial rate of return due to the high initial capital outlay. However, the forecast energy performance of PV systems using standard industry tools can be reasonably reliable, and that current system pricing suggests that photovoltaic technology can produce a reasonable rate of return.
机译:本文介绍了已在伦敦的8个消防局进行了改造的光伏(PV)装置的性能和财务可行性。研究使用不同的方法分析了每个装置的理论性能,并将实际发电量与原始模型数据进行了比较由设计顾问。针对每种安装的本地条件(例如方向,倾斜角度和阴影)评估性能。使用已认可的行业技术和软件包进行建模,以研究重新定位和升级为更高效面板的效果,以确定是否可以实施更好的解决方案。分析表明,能源生产总体上与原始预测相符。设计顾问,为这项技术的性能预测提供一些信心。对光伏装置进行了整个寿命(从安装到退役)的净现值(NPV)和内部收益率(IRR)分析,包括将来更换逆变器和重新安装屋顶的费用。这表明,由于资本支出超过预期(特别是用于更换逆变器),因此该系统没有产生商业上诱人的投资回报率。该研究还研究了采用英国电费补贴(FiT)的效果-这些系统最初不符合条件-这表明可以在25年的系统生命周期内实现简单的投资回报。因此,FiT抵消了与屋顶安装的光伏系统相关的一些风险。研究的结论是,如果不使用适当的补贴,则不能将伦敦8个消防队的当前光伏装置视为可行的金融投资,并且即使由于高昂的初始资本支出,这也无法提供可观的回报率。但是,使用标准行业工具预测的光伏系统的能源性能可以合理可靠,并且当前的系统定价表明光伏技术可以产生合理的回报率。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号