Codes and standards specify minimum performance of HVAC equipment such as water-chilling packages commonly known as chillers. Chiller performance is usually described using two metrics, a full and part-load efficiency. Chiller operation is modeled in building energy simulation software, using a set of performance curves that describe the performance of the equipment as environmental and operational conditions change. While code and standards define the minimum equipment efficiency, simulation-ready performance curves meeting these ever-changing requirements are not typically available. This paper discusses the use of a genetic algorithm to modify typical chiller performance curves to match both full and part-load code minimum efficiency.
机译:规范和标准规定了HVAC设备(例如通常称为冷水机组的冷水机组)的最低性能。冷水机组的性能通常使用两个指标来描述,即满负荷和部分负荷效率。冷水机组的运行在建筑能源模拟软件中建模,使用一组性能曲线来描述随着环境和运行条件的变化设备的性能。尽管代码和标准定义了最低的设备效率,但通常无法获得满足这些不断变化的要求的仿真就绪性能曲线。本文讨论了使用遗传算法修改典型的冷水机组性能曲线,以匹配满载和部分负荷代码的最低效率。