摘要

In order to improve the modeling of air conditioners in building simulation tools, the characteristic curves for total cooling capacity, sensible cooling capacity and energy efficiency ratio of two room units were determined. They were obtained by means of standard capacity tests on climatic chambers in a set of environmental conditions described by external dry- and internal wet bulb temperatures. Afterward, the performance of these two units and that of four other units, with and without taking into to account the thermodynamic variations of the surrounding environments on it, were compared using a whole building simulation program for simulating a conditioned space. The comparative analysis showed that the air conditioner with the higher energy efficiency rating not always provides the lowest power consumption in real conditions of use. (C) 2014 Elsevier Ltd. All rights reserved.
机译:为了改善建筑模拟工具中空调的建模,确定了两个房间单元的总制冷量,显制冷量和能效比的特性曲线。它们是通过在由外部干球和内部湿球温度描述的一组环境条件下在气候箱上进行标准容量测试而获得的。之后,使用整个建筑模拟程序模拟条件空间,比较了这两个单元和其他四个单元的性能,并考虑了是否考虑周围环境的热力学变化。对比分析表明,具有较高能效等级的空调在实际使用条件下并不总是提供最低的能耗。 (C)2014 Elsevier Ltd.保留所有权利。