Dorsal screw penetration following implant removal after volar locked plating of distal radius fracture

机译:radius骨远端plating骨锁定钢板固定后去除种植体后背螺钉穿透

获取原文
获取原文并翻译 | 示例
           

摘要

Complications while removing implants are quite common. In rare cases screw shanks must be left in situ. We present a case of a 38-year-old patient who was treated using a palmar locking plate for a distal radius fracture. After implant removal, one of the screw shanks left in situ penetrated the dorsal cortex of the distal radius into the third extensor tendon compartment and led to irritation of the extensor pollicis longus tendon. We report the unexpected complication and analysis of possible errors of this case to avoid this kind of complication.
机译:移除植入物时的并发症非常普遍。在极少数情况下,必须将螺钉杆留在原处。我们介绍了一个使用手掌锁定板治疗radius骨远端骨折的38岁患者的病例。去除种植体后,留在原处的其中一个螺钉柄穿透radius骨远端的背皮质进入第三伸肌腱隔室,并导致对伸肌的耻骨长肌腱的刺激。我们报告了意料之外的并发症,并分析了这种情况下的可能的错误,以避免这种并发症。