This study outlines a simplified mathematical approach to determine window dimensions for a given room based on two lighting quality indicators, namely, discomfort glare and vertical illuminance. The former represents visual comfort and is expressed in terms of daylight glare index (DGI). The latter reflects on the aspect of receiving sufficient light exposure to maintain optimal health and psychological wellbeing. It is represented by vertical illuminance at the eye level. The result offers a formula that puts forward a simple relationship between the window width, the window height and a specific (desired) depth of a given point in the space. A generic design scenario is used to illustrate the current method. The examined daylighting design criteria are of DGI=20 and E = 2500 lux. In conclusion, this paper proposes the glare criterion as additional to existing national window sizing procedures based on critical illuminance levels (or minimum daylight factor on the working plane corresponding to the critical visual tasks) and critical exterior conditions (that occur with absence of sunlight and a CIE Overcast Sky standard).
机译:这项研究概述了一种基于两个照明质量指标(即不舒适眩光和垂直照度)来确定给定房间的窗户尺寸的简化数学方法。前者代表视觉舒适度,并以日光眩光指数(DGI)表示。后者反映了接受足够的光照以保持最佳健康和心理健康的方面。它由眼睛水平处的垂直照度表示。结果提供了一个公式,该公式提出了窗口宽度,窗口高度与空间中给定点的特定(所需)深度之间的简单关系。通用设计方案用于说明当前方法。检验的采光设计标准为DGI = 20和E = 2500 lux。总之,本文提出了眩光标准,作为基于临界照度水平(或对应于关键视觉任务的工作平面上的最小日光因子)和关键外部条件(在没有阳光和光照的情况下发生)的现有国家窗户尺寸调整程序的补充CIE多云天空标准)。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号