This paper presents a closed-loop control scheme of the AC-DC-AC nine switch converter (NSC) with induction motor operated under dynamic loading conditions. In industries, induction motors are widely used which are operated at lagging power factor and different loading conditions. The electrical distribution company demands high power factor operation, and it gives benefits to the consumer on operating a system closer to unity. The scope of this paper is to control active and reactive power flow between NSC-drive and utility within NSC converter operating constraints. The control scheme is developed such that the active power required for the induction motor is directly transferred from the utility without affecting DC-link voltage. Also, the NSC with induction motor is used to operate at unity power factor and even at leading power factor. On operating NSC at desired leading power factor, the required reactive power at the point of common coupling can be compensated. The proposed control algorithm is implemented in MATLAB software as well as in the hardware. The 5 KVA prototype of NSC is developed in the laboratory. Software and hardware results confirmed the practicability of the proposed control technique.
机译:本文介绍了AC-DC-AC 9开关转换器(NSC)的闭环控制方案,电动电机在动态负载条件下操作。在行业中,广泛使用的感应电动机在滞后功率因数和不同的负载条件下操作。配电公司要求高功率因数操作,并为消费者提供了更靠近统一的系统的利益。本文的范围是在NSC转换器操作约束中控制NSC驱动器和实用程序之间的主动和无功功率流。开发控制方案,使得感应电动机所需的有源电力直接从公用设施转移,而不会影响直流链路电压。而且,具有感应电动机的NSC用于以Unity功率因数甚至处于领先的功率因数。在期望的前导功率因数处工作NSC,可以补偿公共耦合点处所需的无功功率。所提出的控制算法在MATLAB软件以及硬件中实现。 NSC的5 kVA原型是在实验室开发的。软件和硬件结果证实了所提出的控制技术的实用性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号