In the current generation of high-T/sub c/ bolometers the thermal conductance is often chosen for a short time-constant rather than for optimal sensitivity. We describe a novel bolometer bias and readout scheme that promises to relax this constraint. Voltage bias of the superconductor results in strong negative electrothermal feedback that greatly reduces the time-constant of the bolometer. We estimate that a decrease of more than one order of magnitude in time-constant should be possible with existing high-T/sub c/ thermometers. We give theoretical estimates of the performance gain with voltage bias for several bolometers that have been reported in the literature. We find cases where the sensitivity can be greatly improved (by changing the thermal conductance) while holding the time constant fixed and others where the bolometer can be made much faster while maintaining the sensitivity.
机译:在当前的高T / sub c /辐射热计中,通常选择短时间常数而不是最佳灵敏度的热导率。我们描述了一种新颖的辐射热计偏置和读出方案,有望放宽此约束。超导体的电压偏置会导致强烈的负电热反馈,从而大大降低了辐射热计的时间常数。我们估计,使用现有的高T / sub c /温度计,时间常数的下降幅度可能会超过一个数量级。我们给出了几种辐射热计在电压偏置下的性能增益的理论估计值,这些方法在文献中已有报道。我们发现在保持时间常数不变的情况下可以极大地提高灵敏度(通过更改热导率)的情况,在保持灵敏度不变的情况下可以更快地制作辐射热计的情况。