We have been investigating the current imbalance problem comparing the calculated result obtained by the measurement of inductance distribution in multi-strand superconducting cable conductor using high accuracy LCR meter and the measured actual current distribution in it. So far, the measurement of inductance and that of actual current had been carried out at 1 kHz and at few Hz, respectively. As a result, the experimental result did not agree well with the calculated one. It was estimated that the discrepancy between both results was due to the error in the inductance measurement. So, this time, we have carried out inductance measurement more precisely at 100 Hz, and, we have also measured actual current at wider frequency range. From these results, it is concluded that the current distribution is very sensitive to the inductance distribution. Particularly, in multi-stranded conductors with higher magnetic coupling among the strands, such as a large scale and multi twisted cable conductor, the current distribution shows a very dynamic change with the frequency
机译:我们一直在研究电流不平衡问题,将通过使用高精度LCR表测量多股超导电缆导体中的电感分布的测量结果与其中测量的实际电流分布进行比较,得出的计算结果进行了比较。到目前为止,电感和实际电流的测量分别在1 kHz和几Hz下进行。结果,实验结果与计算出的结果不一致。估计两个结果之间的差异是由于电感测量中的误差引起的。因此,这一次,我们以100 Hz进行了更精确的电感测量,并且还测量了更宽频率范围内的实际电流。从这些结果可以得出结论,电流分布对电感分布非常敏感。特别地,在绞合线之间具有较高磁耦合的多绞线导体,例如大型多绞线电缆导体中,电流分布显示出随频率的非常动态的变化。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号