首页> 美国政府科技报告 >Effect of current imbalance on stability of a cable-in-conduit conductor consisting of chrome-plated strands
【24h】

Effect of current imbalance on stability of a cable-in-conduit conductor consisting of chrome-plated strands

机译:电流不平衡对由镀铬钢绞线组成的电缆导管导体稳定性的影响

获取原文

摘要

The effect of an unbalanced current distribution in a conductor consisting of chrome plated strands on stability was investigated using a cable-in-conduit conductor (CICC) consisting of 27 NbTi chrome-plated strands. In addition, the quench behavior when a non-uniform current distribution was produced in the conductor was studied from the experimental results. Moreover, impedance of the chrome-plated strands was measured using the sample conductor. The results show that the stability is determined by the largest strand current when it is sufficiently large otherwise by the transport current when it is not high enough. It was found that it took a long time to make the conductor quench from the onset of the normal transition of the strand carrying the large current. This is explained by the good diffusivity of the coolant temperature in the conductor's cross section. Since the ramp-rate limitation cannot probably take place if the coolant temperature is diffused well in the conductor's cross section, it is expected the ramp-rate limitation can be prevented using this effect. It is also shown that the chrome-plated strands come into contact with one another with uniform transverse conductance on the order of 10(sup 3) S/m. (author)