Gamma ray irradiation tests on high-Tc SQUIDs were carried out to examine their behavior under nuclear reactor environments. The SQUIDs were made of HoBa2Cu3O7-x superconducting thin films on SrTiO3 substrates. Some were encapsulated in glass fiber reinforced epoxy resin. Gamma ray irradiation was performed with a Co-60 gamma ray source. Irradiation dose rates used were 8.1 to 12.2×103 Gy/h (1.0 to 1.5×106 R/h) and the maximum absorption dose was about 10.4 MGy. During and after the irradiation, the noise of the output of the SQUIDs was measured with a power spectrum analyzer. The modulation voltage did not change until a total irradiation dose of about 3 MGy, after which it decreased slightly. We conclude that high-Tc SQUIDs are resistant to gamma ray irradiation and thus the application of high-Tc SQUIDs as sensors for reactor component inspection is promising.
机译:对高Tc SQUID进行了伽马射线辐照试验,以检查它们在核反应堆环境下的行为。 SQUID由在SrTiO3衬底上的HoBa2Cu3O7-x超导薄膜制成。一些被封装在玻璃纤维增​​强的环氧树脂中。用Co-60γ射线源进行γ射线照射。所使用的辐照剂量率为8.1至12.2×103 Gy / h(1.0至1.5×106 R / h),最大吸收剂量约为10.4 MGy。在辐照期间和辐照后,用功率谱分析仪测量SQUID输出的噪声。直到总照射剂量约为3 MGy,调制电压才发生变化,此后电压略有下降。我们得出的结论是,高Tc SQUID对伽马射线辐射有抵抗力,因此将高Tc SQUID用作反应堆组件检查的传感器是有希望的。