This study comprises a continuation of the previous efforts of the authors to characterize different sources of errors in phosphor thermometry based on the determination of luminescence decays from thermographic phosphors. Whereas earlier investigations focused on point detectors utilizing different sensor technology, this work presents a comparison of four PMTs that are identical in terms of their product type. These detectors are supposedly identical, but the investigations revealed that their response is strictly individual. This study also shows a linear excitation energy dependence for the decay time of cadmium tungstate (CdWO4), the phosphor being used in this work. In addition, the potential influence of the intense and short fluorescence peak preceding the weaker and longer exponential decay in some phosphor materials was investigated using the electrical signal gating capability of the PMT. Finally, the evaluated decay time also appeared to be affected by the oscilloscope settings used when recording the phosphorescence signals. The presented results indicate that all operating parameters from the calibration measurement need to be rigorously reproduced in order to avoid systematic temperature errors in phosphor thermometry experiments that are based on reproducible measurements of the decay time. These results should be of more general interest also outside the phosphor community as the findings, presented herein, in principal concern all kinds of measurements that are dependent on reproducible measurements of signal shapes or time transients.
机译:这项研究是作者先前所做工作的延续,这些工作是根据对热成像磷光体的发光衰减的确定来表征磷光体测温误差的不同来源。早期的研究集中在利用不同传感器技术的点检测器上,而这项工作提出了四种产品类型相同的PMT的比较。这些检测器据说是相同的,但调查显示它们的响应严格是个人的。这项研究还显示了钨酸镉(CdWO4)衰减时间的线性激发能量依赖性,该工作中使用的是荧光粉。此外,使用PMT的电信号门控功能,研究了某些荧光粉材料中弱的和长的指数衰减之前强且短的荧光峰的潜在影响。最后,在记录磷光信号时,使用的示波器设置也会影响评估的衰减时间。给出的结果表明,必须严格复制来自校准测量的所有操作参数,以避免荧光粉测温实验中系统的温度误差,该误差基于可重复的衰减时间测量。这些结果也应该在磷光体界之外更普遍地感兴趣,因为本文提出的发现主要涉及依赖于信号形状或时间瞬态的可再现测量的各种测量。

著录项

  • 来源
    《Applied physics 》 |2016年第6期| 170.1-170.12| 共12页
  • 作者单位

    Lund Univ, Div Combust Phys, Dept Phys, Box 118, S-22100 Lund, Sweden;

    Lund Univ, Div Combust Phys, Dept Phys, Box 118, S-22100 Lund, Sweden;

    Lund Univ, Div Combust Phys, Dept Phys, Box 118, S-22100 Lund, Sweden;

    Lund Univ, Div Combust Phys, Dept Phys, Box 118, S-22100 Lund, Sweden;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);美国《生物学医学文摘》(MEDLINE);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号