首页> 外文期刊>Applied physics >An ultra-stable optical frequency standard for telecommunication purposes based upon the 5S(1/2) -> 5D(5/2) two-photon transition in rubidium
【24h】

An ultra-stable optical frequency standard for telecommunication purposes based upon the 5S(1/2) -> 5D(5/2) two-photon transition in rubidium

机译:基于rub的5S(1/2)-> 5D(5/2)双光子跃迁的电信用途超稳定光频率标准

获取原文
获取原文并翻译 | 示例
           

摘要

In this study, we report the development of a frequency standard for optical fiber communication applications based on a two-photon transition in rubidium at 385.2 THz. This standard kills two birds with one stone in the sense it is capable of providing us with two highly stable serviceable wavelengths at 778.1 and 1556.2 nm. In this system, we exploit the narrow line-width of a fiber laser emitting at 1556.2 nm in conjunction with an erbium-doped fiber amplifier to generate a sufficient second harmonic laser beam at 778.1 nm in a periodically polled lithium niobate waveguide mixer in order to probe and frequencylock the laser to the 5S(1/2) (F-g = 3)-5D(5/2) (F-e = 5) hyperfine two-photon transition component in Rb-85. The metrological performance of the standard is evaluated with the aid of an optical frequency comb synthesizer. Allan variance measurement shows a stability of 4 x 10(-12) at 1 s (limited by the comb stability), reaching a floor of 6.8 x 10(-13) at 1000 s. After correction of all the major systematic frequency shifts including the light shift, the absolute frequency is found to be 385 285 142 374.0 (5.0) kHz. Moreover, the absolute frequencies of most of the hyperfine components of the 5S(1/2)-5D(5/2) transition of the two naturally existing rubidium isotopes are measured using a femtosecond frequency comb synthesizer after stabilizing a laser on each component.
机译:在这项研究中,我们报告了基于rub在385.2 THz处的双光子跃迁的光纤通信应用频率标准的开发。该标准可以为我们提供两个高度稳定的波长,分别为778.1和1556.2 nm,因此可以用一块石头杀死两只鸟。在该系统中,我们利用掺6.2光纤放大器在1556.2 nm处发射的光纤激光器的窄线宽在周期性轮询的铌酸锂波导混频器中产生足够的778.1 nm二次谐波激光束,以便探测并锁频激光到Rb-85中的5S(1/2)(Fg = 3)-5D(5/2)(Fe = 5)超细双光子跃迁分量。借助光学频率梳状合成器评估标准品的计量性能。艾伦方差测量显示在1 s时的稳定性为4 x 10(-12)(受梳子稳定性限制),在1000 s时的底限为6.8 x 10(-13)。在校正所有主要的系统频移(包括光频移)后,发现绝对频率为385 285 142 374.0(5.0)kHz。此外,在将激光稳定在每个组分上之后,使用飞秒频率梳状合成器测量了两个天然存在的rub同位素的5S(1/2)-5D(5/2)跃迁的大多数超精细组分的绝对频率。

著录项

  • 来源
    《Applied physics》 |2016年第2期|27.1-27.12|共12页
  • 作者

    Terra Osama; Hussein Hatem;

  • 作者单位

    NIS, POB 136, Giza 12211, Egypt;

    NIS, POB 136, Giza 12211, Egypt;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);美国《生物学医学文摘》(MEDLINE);
  • 原文格式 PDF
  • 正文语种 eng