摘要

We report clear observation of a high voltage (HV) threshold for stable operation in a dc electron gun. The HV hold-off time without any discharge is longer than many hours for operation below the threshold, while it is roughly 10 min above the threshold. The HV threshold corresponds to the minimum voltage where discharge ceases. The threshold increases with the number of discharges during HV conditioning of the gun. Above the threshold, the amount of gas desorption per discharge increases linearly with the voltage difference from the threshold. The present experimental observations can be explained by an avalanche discharge model based on the interplay between electron stimulated desorption (ESD) from the anode surface and subsequent secondary electron emission from the cathode by the impact of ionic components of the ESD molecules or atoms.
机译:我们报告清楚地观察到在直流电子枪中稳定运行的高压(HV)阈值。在低于阈值的条件下运行时,没有任何放电的HV保持时间要比许多小时长,而比阈值高大约10分钟。 HV阈值对应于放电停止的最小电压。阈值随着喷枪的HV调节期间的放电次数而增加。高于阈值,每次放电的气体解吸量随与阈值的电压差线性增加。本实验的观察结果可以通过雪崩放电模型来解释,该模型基于ESD分子或原子的离子成分的影响,从阳极表面的电子激发解吸(ESD)与随后从阴极发出的二次电子之间的相互作用。

著录项

  • 来源
    《Applied Physics Letters》 |2016年第1期|014103.1-014103.4|共4页
  • 作者单位

    High Energy Accelerator Research Organization (KEK), Oho, Tsukuba, Ibaraki 305-0801, Japan;

    National Institutes for Quantum and Radiological Science and Technology (QST), Tokai, Naka,Ibaraki 319-1195, Japan,Institute or Multidisciplinary Research tor Advanced Materials, Tohoku University, Sendai 982-0826, Japan;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);美国《生物学医学文摘》(MEDLINE);