首页> 外文期刊>Applied Mathematical Modelling >A CFD model for the prediction of haemolysis in micro axial left ventricular assist devices
【24h】

A CFD model for the prediction of haemolysis in micro axial left ventricular assist devices

机译:CFD模型预测微轴向左心室辅助设备中的溶血

获取原文
获取原文并翻译 | 示例
       

摘要

This paper describes the development and application of a computational model based upon Computational Fluid Dynamics (CFD) software simulation technology to predict haemolysis in micro Left Ventricular Assist Devices (μLVAD). A CFD model, capturing the full three dimensional geometry of the device, together with an explicit representation of the rotating machinery based upon a rotating reference frame, is solved transiently. Mixed meshes with the order of a million elements are required to resolve the flow adequately and so to enable solutions in a reasonable time (e.g., 3 h) the model is solved on a high performance parallel cluster. Haemolysis is a measure of damage occurring in the blood and is conceived as accumulating as it passes through parts of the device where it encounters high shear forces. As such, the haemolysis model is based upon tracking the behaviour of particles released at the inlet throughout the flow domain and calculating the damage accumulated by each individual particle as it traverses the device. In order to ensure the model predictions of haemolysis are noise free from a statistically significant perspective then it is demonstrated that the number of particles to be tracked must exceed 20000 in any simulation experiment. Comparisons with experimental data from a companion paper demonstrate the effectiveness of the CFD simulation embedding the haemolysis model.
机译:本文介绍了一种基于计算流体动力学(CFD)软件仿真技术的计算模型的开发和应用,该模型可预测微型左心室辅助设备(μLVAD)中的溶血。瞬态求解了CFD模型,该模型捕获了设备的完整三维几何形状,并基于旋转参考系明确显示了旋转机械。需要使用具有百万个元素数量级的混合网格来充分解决流问题,因此要在合理的时间(例如3小时)内启用解决方案,就需要在高性能并行集群上求解模型。溶血是对血液中发生的损伤的一种度量,并且被认为是在血液流经设备中遇到高剪切力的部分时不断累积的结果。这样,溶血模型基于跟踪在整个流域中在入口处释放的粒子的行为,并计算每个单个粒子在穿过设备时累积的损坏。为了从统计学上重要的角度确保溶血的模型预测没有噪音,然后证明了在任何模拟实验中要追踪的粒子数必须超过20000。与随附论文的实验数据进行比较,证明了嵌入溶血模型的CFD模拟的有效性。

著录项

  • 来源
    《Applied Mathematical Modelling》 |2013年第6期|4199-4207|共9页
  • 作者单位

    Civil and Computational Engineering Centre, College of Engineering, Swansea University, Swansea, West Glamorgan, Wales SA2 8PP, UK;

    Civil and Computational Engineering Centre, College of Engineering, Swansea University, Swansea, West Glamorgan, Wales SA2 8PP, UK;

    Civil and Computational Engineering Centre, College of Engineering, Swansea University, Swansea, West Glamorgan, Wales SA2 8PP, UK;

    Civil and Computational Engineering Centre, College of Engineering, Swansea University, Swansea, West Glamorgan, Wales SA2 8PP, UK;

    Civil and Computational Engineering Centre, College of Engineering, Swansea University, Swansea, West Glamorgan, Wales SA2 8PP, UK;

    Calon Cardio-Technology Ltd, Institute of Life Science, Swansea University, Swansea, West Glamorgan, Wales SA2 8PP, UK;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Haemolysis; CFD; Blood pump; Axial flow;

    机译:溶血;差价合约血泵轴流;