A simple theoretical analysis of heat-and-mass transfer to a spherical water-droplet moving in humid air has been made, in connection with the possible use of spray or mist cooling in railway tunnels and other systems. In particular, the histories of the temperature and diameter of the droplet, and the dependence of the time of complete evaporation (or life-time) on the initial size have been studied. The relationships between life-time and the maximum time the droplet may be air borne in the particular environment, (such as a tunnel), has been investigated using the settling time of a freely-falling droplet as a basis of measurement.
机译:结合在铁路隧道和其他系统中可能使用的喷雾或喷雾冷却技术,对在湿空气中移动的球形水滴的传热和传质进行了简单的理论分析。特别地,已经研究了液滴的温度和直径的历史以及完全蒸发的时间(或寿命)对初始尺寸的依赖性。已经使用自由下落的液滴的沉降时间作为测量基础,研究了在特定环境(例如隧道)中液滴在空气中传播的寿命与最长时间之间的关系。

著录项

  • 来源
    《Applied Energy》 |2007年第4期|p.404-412|共9页
  • 作者

    H. Barrow; C.W. Pope;

  • 作者单位

    Department of Engineering, The University of Liverpool, Brownlow Hill, Liverpool, L69 3GH, United Kingdom;