Economic and environmental impact of a combined cooling, heating and power (CCHP) system depends not only on its structure but also on the way it is operated. In this paper, a novel methodology which utilizes overall optimal partial loads of power generation unit (PGU) and novel performance curves (NPC) is proposed to optimize CCHP operation. The PGU overall optimum partial loads for demands below and above the CCHP operating curve are determined based on the optimization criteria and system characteristics. Proposed methodology is flexible and adaptable; it accounts for energy prices, carbon dioxide emissions, primary energy consumption factors and load variations with the weather conditions. Other strategies, such as following match performance, hybrid load, electric load, and thermal load strategies are shown to be the special cases of the NPC methodology. The performance of a CCHP system which operates based on the NPC methodology is compared to the CCHP performances when following match performance, hybrid load, electric load, and thermal load strategies. The comparison is carried out for two small hotel buildings in San Francisco and Miami and residential buildings in Dalian having different energy demand profiles. These locations have different energy prices, carbon dioxide emissions and primary energy consumption factors. The proposed methodology leads to the best operation when compared to other operating strategies based on operating cost, carbon dioxide emissions, primary energy consumption and a combination of them which is not always the case for other operating strategies. Proposed methodology provides a unifying framework which includes all previously operating strategies.
机译:冷热电联产(CCHP)系统的经济和环境影响不仅取决于其结构,还取决于其运行方式。在本文中,提出了一种利用总的最佳发电部分负荷(PGU)和新的性能曲线(NPC)来优化CCHP运行的新方法。根据优化标准和系统特性,确定CCGU工作曲线以下和以上需求的PGU总体最佳局部负荷。拟议的方法具有灵活性和适应性;它考虑了能源价格,二氧化碳排放量,主要能源消耗因子以及负载随天气状况的变化。 NPC方法的特殊情况显示了其他策略,例如跟踪比赛性能,混合负载,电负载和热负载策略。在遵循匹配性能,混合负载,电负载和热负载策略时,将基于NPC方法运行的CCHP系统的性能与CCHP性能进行比较。比较是针对旧金山和迈阿密的两座小型酒店建筑和大连的具有不同能源需求特征的住宅建筑进行的。这些地点的能源价格,二氧化碳排放量和一次能源消耗因子不同。与其他基于运营成本,二氧化碳排放量,一次能源消耗以及它们的组合的运营策略相比,所提出的方法可带来最佳运营,而其他运营策略并不总是如此。拟议的方法提供了一个统一的框架,其中包括以前所有的经营策略。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号