Air flow rate through filters and face masks is one important determinant of the final protection factor of a respiratory protective device in use. Respiratory minute volumes and instantaneous breath flow rates were measured in eight subjects during treadmill work using three types of filtering respirators and one control breathing mask. Work comprised five consecutive bouts of walking at 5 km/h with an increase in elevation of the treadmill by 5% every 5 min and a final walk at 6 km/h and 22.5%. Three subjects managed to complete 5 min at the final work rate. Minute ventilation increased in a curvilinear manner with oxygen uptake and reached 88 ± 20 and 93 ± 20 l/min at 5 km/h (20%) with the control mask and a half mask with filter (SP), respectively. Mean peak inspiratory flow rate (PIFR) was 273 ± 39 for Control and 300 ± 36 for SP at the same work rate. Two power assisted, positive pressure filter respirators (SA and SE) produced higher mask minute volumes at any given work rate compared to respiratory minute volumes in control and SP. PIFR in SA and SE were equal to or lesser than SP. During standardized speech communication, minute volumes decreased. In contrast, PIFR increased by about 100% at low work rates and about 30% at 5 km/h (20%) compared to no speech condition, reaching a highest value of 414 ± 46 l/min for SE. Filter testing is made at a constant flow rate of 95 l/min, a condition that eventually needs to be reconsidered in order to ensure a relevant and valid function test.
机译:通过过滤器和面罩的空气流速是所用呼吸保护装置最终保护因素的重要决定因素。在跑步机工作期间,使用三种类型的过滤式呼吸器和一个控制呼吸面罩,对八名受试者的呼吸分钟量和瞬时呼吸流速进行了测量。工作包括连续5次以5 km / h的速度行走,跑步机每5分钟升高5%,最后以6 km / h的速度和22.5%行走。三名受试者以最终的工作速度设法完成了5分钟。随着氧气的吸收,分钟通气以曲线的方式增加,并在5 km / h(20%)的控制面罩和带过滤器(SP)的半面罩下分别达到88±20和93±20 l / min。在相同的工作速率下,对照的平均吸气峰值流速(PIFR)为273±39,SP的平均峰值吸气流速(PIFR)为300±36。在给定的工作速率下,与对照组和SP的呼吸分钟容积相比,两个动力辅助的正压过滤式呼吸器(SA和SE)产生的面罩分钟容积更高。 SA和SE中的PIFR等于或小于SP。在标准化语音通信过程中,分钟音量减少了。相比之下,与无言语相比,低工作效率下的PIFR增加了约100%,在5 km / h时(20%)增加了约30%,SE的最高值为414±46 l / min。过滤器测试以95 l / min的恒定流速进行,最终需要重新考虑该条件,以确保进行有效的相关测试。

著录项

  • 来源
    《Annals of Occupational Hygiene》 |2007年第3期|327-335|共9页
  • 作者单位

    Thermal Environment Laboratory Division of Ergonomics Department of Design Sciences Faculty of Engineering Lund University Sweden;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);美国《化学文摘》(CA);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

  • 入库时间 2022-08-18 01:11:26

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号