...
首页> 外文期刊>Analytical Letters >Comparative Study of Electrospray and Atmospheric Pressure Chemical Ionization with Liquid Chromatography-Mass Spectrometry for Quantification of Five Antihyperglycemic Agents Utilizing Monolithic Column
【24h】

Comparative Study of Electrospray and Atmospheric Pressure Chemical Ionization with Liquid Chromatography-Mass Spectrometry for Quantification of Five Antihyperglycemic Agents Utilizing Monolithic Column

机译:液相色谱-质谱联用电喷雾和大气压化学电离定量分析五种使用整体柱的降糖药的比较研究

获取原文
获取原文并翻译 | 示例
           

摘要

Liquid chromatography-mass spectrometry (LC-MS) in atmospheric pressure chemical ionization (APCI) and electrospray ionization (ESI) modes were studied for a multi-component plasma and urine quantification of 5 antihyperglycemic agents (metformin, pioglitazone, gliclazide, glibenclamide, and glimperide). The separation of the compounds was achieved using Chromolith Performance RP-18e column (100 × 4.6 mm), with gradient mobile phase composition of acetonitrile −0.1% formic acid. MS parameters for APCI and ESI were optimized individually and were operated in positive mode. The detection limits for the metformin, pioglitazone, glibenclamide, and glimepiride were determined to be 6.84, 6.22, 13.03, and 44.38 ng mL−1 using LC-ESI-MS; and for LC-APCI-MS, it was determined to be 48.39, 8.02, 17.02, and 144.55 ng mL−1, respectively. Gliclazide was the only exception as it exhibited a lower limit of detection (LOD) using APCI than ESI which was found to be 5.61 and 23.43 ng mL−1, respectively. The method was validated for system suitability, linearity, precision and accuracy, specificity, stability, and robustness. The ESI as compared to APCI was found superior in many analytical parameters. The assay has been applied successfully to biological fluids (plasma and urine) of healthy volunteers.View full textDownload full textKeywordsAntihyperglycemic, APCI, ESI, LC-MS, MonolithRelated var addthis_config = { ui_cobrand: "Taylor & Francis Online", services_compact: "citeulike,netvibes,twitter,technorati,delicious,linkedin,facebook,stumbleupon,digg,google,more", pubid: "ra-4dff56cd6bb1830b" }; Add to shortlist Link Permalink http://dx.doi.org/10.1080/00032719.2012.680054
机译:研究了大气压化学电离(APCI)和电喷雾电离(ESI)模式下的液相色谱-质谱(LC-MS)用于血浆和尿液中5种抗高血糖药(二甲双胍,吡格列酮,格列齐特,格列本脲和格列本脲)。化合物的分离是使用Chromolith Performance RP-18e色谱柱(100×4.6 mm),使用乙腈– 0.1%甲酸的梯度流动相组成。分别优化了APCI和ESI的MS参数,并以肯定模式运行。使用LC-ESI-MS确定二甲双胍,吡格列酮,格列本脲和格列美脲的检出限为6.84、6.22、13.03和44.38 ng mL ;对于LC-APCI-MS,分别确定为48.39、8.02、17.02和144.55 ng mL ˆ1 。格列齐特是唯一的例外,因为它使用APCI的检测下限(LOD)比ESI低,分别为5.61和23.43 ng mL ˆ1 。验证了该方法的系统适用性,线性,精度和准确性,特异性,稳定性和鲁棒性。与APCI相比,ESI在许多分析参数上均表现出色。该测定法已成功应用于健康志愿者的生物体液(血浆和尿液)。查看全文下载全文关键字抗高血糖,APCI,ESI,LC-MS,Monolith相关变量var addthis_config = {ui_cobrand:“泰勒和弗朗西斯在线”,service_compact:“ citeulike ,netvibes,twitter,technorati,可口,linkedin,facebook,stumbleupon,digg,google,更多”,发布:“ ra-4dff56cd6bb1830b”};添加到候选列表链接永久链接http://dx.doi.org/10.1080/00032719.2012.680054

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号