首页> 外文期刊>分析化学 >Development of a gas detector tube to measure dimethylsulfide in city gas based on liquefied natural gas
【24h】

Development of a gas detector tube to measure dimethylsulfide in city gas based on liquefied natural gas

机译:基于液化天然气的城市煤气中二甲基硫的气体检测管的研制

获取原文
获取原文并翻译 | 示例
           

摘要

The odorant blend of tertiary butylmercaptan (TBM) and dimethylsulfide (DMS) is generally used as an odorant in city gas based on liquefied natural gas. The concentra- tions of both TBM and DMS in city gas are about 2 volppm. To control the quality of city gas, a simple method is required to determine the odorant concentration at the end of gas pipelines. This paper reports on the development of a gas detector tube which can measure the DMS concentration in city gas.
机译:叔丁基硫醇(TBM)和二甲基硫醚(DMS)的加味剂混合物通常用作基于液化天然气的城市煤气中的加味剂。城市燃气中TBM和DMS的浓度均为2 volppm。为了控制城市燃气的质量,需要一种简单的方法来确定燃气管道末端的气味浓度。本文报告了一种可检测城市燃气中DMS浓度的气体检测管的开发情况。