Does the Mass Spectrometer Define the Marker? A Comparison of Global Metabolite Profiling Data Generated Simultaneously via UPLC-MS on Two Different Mass Spectrometers

机译:质谱仪是否定义标记?在两种不同质谱仪上通过UPLC-MS同时生成的全球代谢物分析数据的比较

获取原文
获取原文并翻译 | 示例
           

摘要

By coupling a single UPLC separation to two differentntypes of mass spectrometer an unbiased comparison ofnthe metabolite profiles produced by each instrument forna set of rat urine samples was obtained. The flow fromnthe UPLC column was split equally and both streams ofneluent were simultaneously directed to the inlets of thentwo mass spectrometers. Mass spectrometry on the eluentnwas undertaken using a triple quadrupole linear ion trapnand a hybrid quadrupole time-of-flight mass spectrometernusing both positive and negative ESI. Data from both massnspectrometers were subjected to multivariate statisticalnanalysis, after applying the same data extraction software,nand showed the same general pattern of correlationnbetween the samples using both unsupervised and supervisednmethods of statistical analysis. Based on orthogonalnpartial least-squares discriminant analysis modelsna number of ions were recognized as “responsible”nfor the separation of the animal groups. From the peaksndetected, and denoted as significant by the statisticalnanalysis a number of ions were found to be unique to onendata set or the other, a result which may have consequencesnfor biomarker discovery and interlaboratoryncomparisons. The software package used for data analysisnalso had an effect on the outcome of the statisticalnanalysis.
机译:通过将单个UPLC分离物耦合到两种不同类型的质谱仪,就可以对每种仪器在大鼠尿液样本中产生的代谢物谱进行无偏比较。来自UPLC色谱柱的流量被均分,两种洗脱剂流同时导入两个质谱仪的入口。洗脱液的质谱是使用三重四极杆线性离子阱和混合四极杆飞行时间质谱仪同时使用正和负ESI进行的。使用相同的数据提取软件后,对两个质谱仪的数据进行了多元统计分析,并且使用统计分析的无监督方法和监督方法显示了样品之间相关性的一般模式。根据正交偏最小二乘判别分析模型,离子数量被认为是“负责任”的动物群的分离。从检测到的峰中,并通过统计分析将其表示为显着的,发现离子对数据集或其他数据集是唯一的,其结果可能对生物标记物的发现和实验室间的比较产生影响。用于数据分析的软件包也对统计分析的结果产生影响。

著录项

  • 来源
    《Analytical Chemistry》 |2010年第19期|p.8226-8234|共9页
  • 作者单位

    Department of Chemistry, Aristotle University Thessaloniki, 541 24 Thessaloniki, Greece, Umetrics U.K., Unit 3-4Cowley Way, Weston Road, Crewe, Cheshire, CW1 6AG, United Kingdom, RTI International, 3040 Cornwallis Drive,Research Triangle Park, North Carolina 27709, and AstraZeneca, Department of Clinical Pharmacology, DrugMetabolism and Pharmacokinetics, Mereside, Alderley Park, Macclesfield, Cheshire, SK10 4TG U.K.;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);美国《生物学医学文摘》(MEDLINE);美国《化学文摘》(CA);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号