During stent development, accurate monitoring of the drug concentration in animal tissues can provide critical information on how the drug is released into the circulation and the surrounding tissues. To establish the relationship between the drug concentration and the distance from the stent to the target tissue, a comprehensive strategy was developed for sample collection, sample homogenization and sample storage as well as sample analysis. This strategy was developed with the analytical chemists and animal surgical specialists working together as a team. The optimized sampling process was designed to yield a representative sample, appropriately located and of an appropriate size. The sampling process was also designed to eliminate the potential for carryover and cross-contamination. During sample processing, the analyte solution was spiked into blank tissues using a sharp needle and a gas-tight syringe to prepare tissue quality control samples. These tissue quality controls were then used to evaluate the stability of the drug in solid tissue and homogenate, the homogenization carryover, the cross-contamination and the recovery of the drug during method validation and to monitor the overall process of drug analysis of the swine tissues. This thorough strategy has been applied to the accurate determination of zotarolimus in swine tissues for regulated toxicology studies. The entire process was controlled, including precise tissue sampling, compound-based tissue homogenization, method validation, and the application of the method to regulated toxicokinetics studies. The results demonstrate that analytical chemistry concepts can be successfully integrated into toxicokinetics studies in order to collect precise samples and obtain meaningful results. The strategy can be applied to similar toxicokinetics studies of locally administrated drugs in tissues.
机译:在支架开发过程中,对动物组织中药物浓度的准确监控可以提供有关药物如何释放到循环系统和周围组织中的重要信息。为了建立药物浓度和从支架到靶组织的距离之间的关系,开发了一种用于样品收集,样品均质化和样品存储以及样品分析的综合策略。该策略是由分析化学家和动物外科专家共同合作开发的。设计了优化的采样过程以产生具有代表性的样本,其位置适当且大小适当。采样过程还旨在消除残留和交叉污染的可能性。在样品处理过程中,使用锋利的针头和气密注射器将分析物溶液掺入空白组织中,以制备组织质量控制样品。然后将这些组织质量控制用于评估药物在实体组织和匀浆中的稳定性,匀浆残留,交叉污染和药物在方法验证期间的回收率,并监测猪组织的药物分析总体过程。这种彻底的策略已被应用于准确测定猪组织中的佐他莫司,用于调节毒理学研究。整个过程都受到控制,包括精确的组织采样,基于化合物的组织均质化,方法验证以及该方法在规范的毒物动力学研究中的应用。结果表明,分析化学概念可以成功地整合到毒物动力学研究中,以收集精确的样品并获得有意义的结果。该策略可应用于组织中局部给药药物的类似毒代动力学研究。

著录项

  • 来源
    《Analytical and Bioanalytical Chemistry》 |2007年第8期|2745-2756|共12页
  • 作者单位

    Department of Drug Analysis Abbott Laboratories 100 Abbott Park Road Abbott Park IL 60064 USA;

    Department of Drug Analysis Abbott Laboratories 100 Abbott Park Road Abbott Park IL 60064 USA;

    Department of Drug Analysis Abbott Laboratories 100 Abbott Park Road Abbott Park IL 60064 USA;

    Department of Drug Analysis Abbott Laboratories 100 Abbott Park Road Abbott Park IL 60064 USA;

    Department of Drug Analysis Abbott Laboratories 100 Abbott Park Road Abbott Park IL 60064 USA;

    Abbott Vascular Division 200 Abbott Park Road Abbott Park IL 60064 USA;

    Abbott Vascular Division 200 Abbott Park Road Abbott Park IL 60064 USA;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Zotarolimus; Tissue; Sampling; Homogenization; LC–MS/MS;

    机译:佐他莫司;组织;取样;均质;LC-MS / MS;

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号