首页> 外文期刊>Analytical and Bioanalytical Chemistry >Analytical determination of specific 4,4′-methylene diphenyl diisocyanate hemoglobin adducts in human blood
【24h】

Analytical determination of specific 4,4′-methylene diphenyl diisocyanate hemoglobin adducts in human blood

机译:人体血液中特定4,4'-亚甲基二苯基二异氰酸酯血红蛋白加合物的分析测定

获取原文
获取原文并翻译 | 示例
           

摘要

4,4′-Methylene diphenyl diisocyanate (MDI) is one of the most important isocyanates in the industrial production of polyurethane and other MDI-based synthetics. Because of its high reactivity, it is known as a sensitizing agent, caused by protein adducts. Analysis of MDI is routinely done by determination of the nonspecific 4,4′-methylenedianiline as a marker for MDI exposure in urine and blood. Since several publications have reported specific adducts of MDI and albumin or hemoglobin, more information about their existence in humans is necessary. Specific adducts of MDI and hemoglobin were only reported in rats after high-dose MDI inhalation. The aim of this investigation was to detect the hemoglobin adduct 5-isopropyl-3-[4-(4-aminobenzyl)phenyl]hydantoin (ABP-Val-Hyd) in human blood for the first time. We found values up to 5.2 ng ABP-Val-Hyd/g globin (16 pmol/g) in blood samples of workers exposed to MDI. Because there was no information available about possible amounts of this specific MDI marker, the analytical method focused on optimal sensitivity and selectivity. Using gas chromatography–high-resolution mass spectrometry with negative chemical ionization, we achieved a detection limit of 0.02 ng ABP-Val-Hyd/g globin (0.062 pmol/g). The robustness of the method was confirmed by relative standard deviations between 3.0 and 9.8 %. Combined with a linear detection range up to 10 ng ABP-Val-Hyd/g globin (31 pmol/g), the enhanced precision parameter demonstrates that the method described is optimized for screening studies of the human population.
机译:4,4'-亚甲基二苯基二异氰酸酯(MDI)是聚氨酯和其他基于MDI的合成物工业生产中最重要的异氰酸酯之一。由于其高反应性,它被称为由蛋白质加合物引起的敏化剂。 MDI的分析通常通过确定非特异性的4,4'-亚甲基二苯胺作为尿液和血液中MDI暴露的标志物来进行。由于一些出版物已经报道了MDI和白蛋白或血红蛋白的特定加合物,因此需要更多有关它们在人类中的存在的信息。仅在大剂量吸入MDI后的大鼠中报告了MDI和血红蛋白的特定加合物。这项研究的目的是第一次检测人血中的血红蛋白加合物5-异丙基-3- [4-(4-氨基苄基)苯基]乙内酰脲(ABP-Val-Hyd)。我们在接触MDI的工人血液样本中发现的血红蛋白值高达5.2ng ABP-Val-Hyd / g(16 pmol / g)。由于没有有关此特定MDI标记物可能含量的信息,因此分析方法侧重于最佳灵敏度和选择性。使用具有负化学电离作用的气相色谱-高分辨率质谱法,我们达到了0.02 ng ABP-Val-Hyd / g球蛋白(0.062 pmol / g)的检出限。该方法的鲁棒性通过3.0至9.8%的相对标准偏差进行了确认。结合高达10 ng ABP-Val-Hyd / g球蛋白(31 pmol / g)的线性检测范围,增强的精密度参数表明所描述的方法针对人群的筛选研究进行了优化。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号