首页> 外文期刊>Anaesthesia >Comparison of three videolaryngoscopes: Pentax Airway Scope, C-MAC™, Glidescope® vs the Macintosh laryngoscope for tracheal intubation†
【24h】

Comparison of three videolaryngoscopes: Pentax Airway Scope, C-MAC™, Glidescope® vs the Macintosh laryngoscope for tracheal intubation†

机译:三种视频喉镜的比较:Pentax Airway Scope,C-MAC™,Glidescope®与用于气管插管的Macintosh喉镜†

获取原文
获取原文并翻译 | 示例
           

摘要

SummaryWe compared the intubating characteristics of the Pentax Airway Scope, the C-MAC™ and the Glidescope® with those of the Macintosh laryngoscope in 400 patients without predictors of difficult intubation. We found shorter intubation times with the Airway Scope (mean (SD) 20.6 (11.5) s) compared with the C-MAC (31.9 (17.6) s) and Glidescope (31.2 (15.0) s), p < 0.001. The median (IQR [range]) score for ease of intubation was significantly lower (better) with the Airway Scope (0 (0–8.75 [0–60])) than with the C-MAC (10 (0–20 [0–90])) or Glidescope (0 (0–20 [0–80])), p < 0.001. Ease of blade insertion in the C-MAC (0 (0–0 [0–30])) was superior to that of the Airway Scope (0 (0–0 [0–70])), Macintosh (0 (0–0 [0–80])) or Glidescope (0 (0–10 [0–60])), p = 0.006. More patients had a grade 1 laryngeal view with the Airway Scope (97%) compared with the C-MAC (87%), Glidescope (78%), or Macintosh (58%), p < 0.001. There were no grade 3 laryngeal views with the Airway Scope. The three videolaryngoscopes had comparable first attempt successful intubation rates: 95% for the Airway Scope, 93% for the C-MAC and 91% for the Glidescope.
机译:总结我们比较了Pentax气道镜,C-MAC™和Glidescope ®与Macintosh喉镜的插管特征,对400例没有困难插管的患者进行了比较。我们发现,气道镜(平均(SD)20.6(11.5)s)与C-MAC(31.9(17.6)s)和Glidescope(31.2(15.0)s)相比,插管时间更短,p <0.001。气管镜(0(0–8.75 [0–60]))的插管简便性中位数(IQR [范围])得分明显低于(更好),而C-MAC(10(0–20 [0] –90])或Glidescope(0(0–20 [0–80])),p <0.001。刀片插入C-MAC(0(0–0 [0–30]))的难度比气道镜(0(0–0 [0–70])),Macintosh(0(0–0–0) 0 [0–80]))或Glidescope(0(0–10 [0–60])),p = 0.006。与C-MAC(87%),Glidescope(78%)或Macintosh(58%)相比,使用气道镜(97%)的1级喉镜患者更多,p <0.001。气道镜没有3级喉镜检查。三种电子喉镜的首次成功插管率相当:气道镜95%,C-MAC 93%,滑翔镜91%。

著录项

  • 来源
    《Anaesthesia》 |2010年第11期|p.1126-1132|共7页
  • 作者单位

    Consultant;

    Medical Officer Trainee, Ministry of Health Holdings Pte Ltd, Singapore;

    Senior Consultant;

    Senior Consultant and Head, Department of Women’s Anaesthesia, KK Women’s and Children’s Hospital, Singapore;