首页> 外文期刊>Anaesthesia >Determination of the optimal stylet strategy for the C-MAC® videolaryngoscope
【24h】

Determination of the optimal stylet strategy for the C-MAC® videolaryngoscope

机译:确定C-MAC®视频喉镜的最佳管心针策略

获取原文
获取原文并翻译 | 示例
           

摘要

SummaryThe C-MAC® videolaryngoscope is a novel intubation device that incorporates a camera system at the end of its blade, thereby facilitating obtaining a view of the glottis without alignment of the oral, pharyngeal and tracheal axes. It retains the traditional Macintosh blade shape and can be used as a direct or indirect laryngoscope. We wished to determine the optimal stylet strategy for use with the C-MAC. Ten anaesthetists were allowed up to three attempts to intubate the trachea in one easy and three progressively more difficult laryngoscopy scenarios in a SimMan® manikin with four tracheal tube stylet strategies: no stylet; stylet; directional stylet (Parker Flex-It™); and hockey-stick stylet. The use of a stylet conferred no advantage in the easy laryngoscopy scenario. In the difficult scenarios, the directional and hockey-stick stylets performed best. In the most difficult scenario, the median (IQR [range]) duration of the successful intubation attempt was lowest with the hockey-stick stylet; 18 s (15–22 [12–43]) s, highest with the unstyletted tracheal tube; 60 s (60–60 [60, 60]) s and styletted tracheal tube 60 s (29–60 [18–60]) s, and intermediate with the directional stylet 21 s (15–60 [8–60]) s. The use of a stylet alone does not confer benefit in the setting of easy laryngoscopy. However, in more difficult laryngoscopy scenarios, the C-MAC videolaryngoscope performs best when used with a stylet that angulates the distal tracheal tube. The hockey-stick stylet configuration performed best in the scenarios tested.
机译:总结C-MAC ®喉镜是一种新颖的插管设备,在其刀片的末端装有摄像头系统,因此无需对准口腔,咽喉和气管轴即可获得声门的视野。它保留了传统的Macintosh刀片形状,可用作直接或间接喉镜。我们希望确定与C-MAC一起使用的最佳管心针策略。十名麻醉师在使用Simman ®人体模型的四种简单气管插管策略中,在一种简单的和三种难度越来越大的喉镜检查方案中,最多可以进行三次气管插管尝试。探针定向探针(Parker Flex-It™);和曲棍球棒探针。在简易的喉镜检查情况下,使用管心针没有任何优势。在困难的情况下,方向性和曲棍球探针的表现最佳。在最困难的情况下,曲棍球棒通气管成功插管尝试的中位时间(IQR [range])最低。 18 s(15-22 [12-43])s,未通气管导管时最高; 60 s(60–60 [60–60])s和带探针的气管管60 s(29–60 [18–60])s,中间有方向性探针21 s(15–60 [8–60])s 。单独使用管心针并不能使喉镜检查更加方便。但是,在更困难的喉镜检查情况下,C-MAC电子喉镜在与管形远端气管导管的通管针配合使用时性能最佳。曲棍球棒探针配置在测试的场景中表现最佳。

著录项

  • 来源
    《Anaesthesia》 |2010年第4期|p.369-378|共10页
  • 作者单位

    Clinical Research Fellow|Consultant Anaesthetist|Clinical Research Faculty, National University of Ireland, Galway, Ireland;

    Clinical Research Fellow;

    Consultant Anaesthetist;

    Consultant Anaesthetist|Senior Clinical Lecturer|Clinical Research Faculty, National University of Ireland, Galway, Ireland;

    Consultant Anaesthetist|Professor of Anaesthesia, Department of Anaesthesia, Galway University Hospitals|Clinical Research Faculty, National University of Ireland, Galway, Ireland;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号