首页> 外文期刊>American journal of applied sciences >Effects of Plastic Wedges on Whole Foot Radiograph in Anteroposterior and Oblique Positions
【24h】

Effects of Plastic Wedges on Whole Foot Radiograph in Anteroposterior and Oblique Positions

机译:塑料楔对前后位和斜位全足X光片的影响

获取原文
获取原文并翻译 | 示例

摘要

The whole foot radiography may be taken twice with different exposure parameters. It produces two images in two radiation exposures; one is the metatarsal view of the phalange and the other is a tarsal view. The aim of this study was to study the effects of plastic wedges on whole foot radiography with one radiation exposure. The plastic wedge was developed from plastic wood. Whole foot phantom radiographic imaging was created in anteroposterior and oblique positions with and without plastic wedges mounted on the collimator of an X-ray machine. A radiation imaging plate was used as a transmitted-radiation receptor. The radiation exposure parameter was 54 kilo-voltage at 100 milliamperes for 0.02 sec. The results showed that the resolution of whole foot phantom radiographic imaging in both anteroposterior and oblique positions with plastic wedge mounted on a collimator of an X-ray machine was better than without plastic wedge mounted on collimator. Percentage of Coefficient Variance (%CV) of pixel value on radiographic imaging with plastic wedge mounted on collimator was less than without plastic wedge mounted on collimator. This finding suggests that plastic wedges can help improve image quality of whole foot radiography with one radiation exposure.
机译:整个足部射线照相可以用不同的曝光参数拍摄两次。它在两次辐射曝光中产生两幅图像。一个是指骨的meta骨视图,另一个是a骨视图。这项研究的目的是研究一种塑料楔子在一次辐射下对整个足部射线照相的影响。塑料楔由塑料木制成。在X射线机的准直仪上安装和不安装塑料楔块的情况下,在前后和倾斜位置创建全脚幻影X射线摄影图像。将放射线成像板用作透射放射线受体。辐射暴露参数为100毫安时54千伏电压,持续0.02秒。结果表明,在X射线机的准直仪上安装塑料楔形块,在前后位和斜位全足体模射线照相成像的分辨率都比未在准直仪上安装塑料楔形块的分辨率高。将塑料楔安装在准直仪上的射线照相成像像素值的系数方差百分比(%CV)小于未将塑料楔安装在准直仪上的像素值。这一发现表明,塑料楔形可以通过一次辐射照射来帮助改善整个足部X射线照相的图像质量。

著录项

  • 来源
    《American journal of applied sciences 》 |2017年第4期| 511-516| 共6页
  • 作者单位

    Department of Radiologic Technology, Faculty of Associated Medical Sciences,Chiang Mai University, Chiang Mai, Thailand 50200, Thailand;

    Department of Radiologic Technology, Faculty of Associated Medical Sciences,Chiang Mai University, Chiang Mai, Thailand 50200, Thailand;

    Department of Radiologic Technology, Faculty of Associated Medical Sciences,Chiang Mai University, Chiang Mai, Thailand 50200, Thailand;

    Department of Radiologic Technology, Faculty of Associated Medical Sciences,Chiang Mai University, Chiang Mai, Thailand 50200, Thailand;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Foot Radiography; Plastic Wedge; Image Quality;

    机译:足部放射照相;塑料楔;画面质量;