This tutorial paper describes a procedure for designing a network that simulates the image impedance of a loaded cable. The problem is reduced to one of synthesizing three 2-terminal impedances, two at one frequency and the third at three frequencies. In general, the return loss performance of the network against the facility is greater than 30 db (decibels) over the frequency range from 0.006 to six times the cutoff frequency, and is greater than 40 db over most of the transmitted band. With the aid of artificial cable and a loading coil, such networks can be used to simulate both the transmission and impedance characteristics of any type of loaded cable facility having any fractional length of end section.
机译:本教程文件介绍了一种设计网络的过程,该网络可模拟已加载电缆的图像阻抗。问题被简化为合成三个2端子阻抗之一,两个合成一个阻抗,第三个合成阻抗在三个频率。通常,在相对于截止频率的0.006到6倍的频率范围内,网络针对设施的回波损耗性能大于30 db(分贝),而在大多数传输频段上大于40 db。借助于人造电缆和负载线圈,这样的网络可用于模拟任何类型的,具有任何端部长度的负载电缆设施的传输和阻抗特性。