首页> 外文期刊>Acoustics bulletin >Lessons learned from acoustic testing in schools in the south-west of England
【24h】

Lessons learned from acoustic testing in schools in the south-west of England

机译:从英格兰西南部学校的声学测试中学到的经验教训

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

Results from acoustical testing in schools have revealed the following common problems and possible solutions.rn1. Noise ingress is highly site-dependent. Ingress with unattenuated natural ventilation can be minimised by providing cross-ventilation to reduce the areas of opening required. Modelling open windows as non-attenuating holes matches well withrnsite measurements.rn2. To be compliant, mechanical ventilation systems need to incorporate appropriate levels of acoustic attenuation. Wall or ceiling-mounted fans are unlikely to comply.
机译:学校声学测试的结果表明存在以下常见问题和可能的解决方案。噪声进入高度依赖于站点。通过提供交叉通风以减少所需的开口面积,可以最大程度地减少自然通风的进入。将打开的窗口建模为非衰减孔与现场测量非常吻合。为了符合要求,机械通风系统需要结合适当水平的声衰减。壁挂式或吊顶式风扇不太可能符合要求。

著录项

  • 来源
    《Acoustics bulletin》 |2010年第2期|p.3436-38|共4页
  • 作者

    Thomas A Mitchell;

  • 作者单位

    Centre for Energy and the Environment, School of Physics, University of Exeter;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号