External quality assessment for molecular typing of Salmonella 2013–2015: performance of the European national public health reference laboratories

机译:2013-2015年沙门氏菌分子分型的外部质量评估:欧洲国家公共卫生参考实验室的绩效

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

We report the results of three consecutive External Quality Assessments (EQAs) for molecular subtyping of Salmonella to assess the performance of the European national public health reference laboratories (NPHRLs). The EQA included the molecular typing methods used for European enhanced surveillance of human Salmonella infections: pulsed field gel electrophoresis (PFGE), including gel analysis by the use of the software BioNumerics, and 5-locus multiple locus variable number of tandem repeat analysis (MLVA) for serovar Typhimurium. The participation in the PFGE laboratory part was higher (27/35) than in the gel analysis (19/35) and MLVA (15/35), suggestive of the need for capacity building in methods requiring specialized equipment (MLVA) or software (gel analysis). The majority (25/27) of the participating NPHRLs produced inter-laboratory comparable PFGE gel(s). Two laboratories continued to produce low-quality gels and should have additional technical assistance in the future. In particular, two gel quality evaluation parameters, measuring “image acquisition and running conditions” and “bands”, were identified to cause gel quality problems throughout the EQAs. Despite the high number of laboratories participating in the PFGE laboratory part, the participation in gel analysis was low, although increasing. In the MLVA part, the NPHRLs correctly assigned 96% (405/420) allelic profiles according to the nomenclature. In conclusion, the EQAs identified critical parameters for unsuccessful performance and helped to offer assistance to those laboratories that needed it most. The assessments supported the development of quality in molecular typing and promoted the harmonization of subtyping methods used for EU/EEA-wide surveillance of human Salmonella infections.
机译:我们报告了沙门氏菌的分子亚型的三个连续的外部质量评估(EQA)的结果,以评估欧洲国家公共卫生参考实验室(NPHRLs)的性能。 EQA包括用于欧洲增强的人类沙门氏菌感染监测的分子分型方法:脉冲场凝胶电泳(PFGE),包括使用BioNumerics软件进行凝胶分析,以及5位点多基因座可变数目的串联重复序列分析(MLVA) )用于鼠伤寒血清。 PFGE实验室部分的参与率(27/35)高于凝胶分析(19/35)和MLVA(15/35)的参与度,这表明需要使用专用设备(MLVA)或软件的方法进行能力建设(凝胶分析)。大多数(25/27)参与的NPHRL生产实验室间可比的PFGE凝胶。两个实验室继续生产低质量的凝胶,将来应该获得更多的技术援助。特别是,确定了两个凝胶质量评估参数,分别测量“图像采集和运行条件”和“条带”,以引起整个EQA的凝胶质量问题。尽管参与PFGE实验室部分的实验室数量众多,但凝胶分析的参与量虽然有所增加,但仍然很低。在MLVA部分,NPHRL根据命名正确分配了96%(405/420)等位基因。总之,EQA确定了导致性能不佳的关键参数,并帮助向最需要性能的实验室提供帮助。这些评估支持了分子分型质量的发展,并促进了用于欧盟/欧洲经济区范围的人类沙门氏菌感染监测的分型方法的统一。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号